Characteristics of Posterior Corneal Astigmatism in Cataract Patients with High Myopia

Wen-jie Liu, Jie-wei Liu, Jing-jing Wang, Qi Wang
{"title":"Characteristics of Posterior Corneal Astigmatism in Cataract Patients with High Myopia","authors":"Wen-jie Liu, Jie-wei Liu, Jing-jing Wang, Qi Wang","doi":"10.3760/CMA.J.ISSN.1674-845X.2019.11.002","DOIUrl":null,"url":null,"abstract":"Objective: \nTo evaluate the characteristics of posterior corneal astigmatism (PA) in cataract patients with high myopia. \n \n \nMethods: \nIn this series of case study, 215 eyes of 215 patients from Shanxi Eye Hospital were recruited from January to June 2018 and divided into a high myopia group (94 patients, 94 eyes) and a control group (121 patients, 121 eyes). PA, total corneal astigmatism (TA) and simulated keratometric astigmatism (KA) were measured by arotating Scheimplfulg camera (Pentacam HR). The error produced by TA using KA was calculated with vector and arithmetical analysis. Data were analyzed by t test and correlation analysis \n \n \nResults: \nIn the high myopia group, the mean magnitude of the pa was -0.33±0.20 D, and exceeded 0.5 D in 30.8%. The steepest meridian was vertically aligned in 79.6% of the cases. In the control group, the mean magnitude of the PA was -0.31±0.18 D. There was no significant difference in PA between the high myopia group and the control group (t=0.589, P=0.557). In the high myopia group, the vector error between KA and TA was (0.12±0.21) D@4°. There was a correlation between the magnitude of PA and KA, PA and Km (KA), and PA and Km (PA) (r=0.340, P=0.001; r=0.285, P=0.006; r=0.333, P=0.001). For KA>0.5 D patients, the difference in magnitude between ta and Ka significantly increased with an increase in the magnitude of pa (r=0.235, P=0.004). \n \n \nConclusion: \nThere was no significant difference in PA between the high myopia group and the control group. In the high myopia group, neglecting PA may lead to an incorrect estimate of ta. Personalized PA should be considered in patients with Toric intraocular lens implants. \n \n \nKey words: \nposterior corneal astigmatism; high myopia; cataract","PeriodicalId":10142,"journal":{"name":"Chinese Journal of Optometry & Ophthalmology","volume":"88 1","pages":"807-812"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chinese Journal of Optometry & Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3760/CMA.J.ISSN.1674-845X.2019.11.002","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To evaluate the characteristics of posterior corneal astigmatism (PA) in cataract patients with high myopia. Methods: In this series of case study, 215 eyes of 215 patients from Shanxi Eye Hospital were recruited from January to June 2018 and divided into a high myopia group (94 patients, 94 eyes) and a control group (121 patients, 121 eyes). PA, total corneal astigmatism (TA) and simulated keratometric astigmatism (KA) were measured by arotating Scheimplfulg camera (Pentacam HR). The error produced by TA using KA was calculated with vector and arithmetical analysis. Data were analyzed by t test and correlation analysis Results: In the high myopia group, the mean magnitude of the pa was -0.33±0.20 D, and exceeded 0.5 D in 30.8%. The steepest meridian was vertically aligned in 79.6% of the cases. In the control group, the mean magnitude of the PA was -0.31±0.18 D. There was no significant difference in PA between the high myopia group and the control group (t=0.589, P=0.557). In the high myopia group, the vector error between KA and TA was (0.12±0.21) D@4°. There was a correlation between the magnitude of PA and KA, PA and Km (KA), and PA and Km (PA) (r=0.340, P=0.001; r=0.285, P=0.006; r=0.333, P=0.001). For KA>0.5 D patients, the difference in magnitude between ta and Ka significantly increased with an increase in the magnitude of pa (r=0.235, P=0.004). Conclusion: There was no significant difference in PA between the high myopia group and the control group. In the high myopia group, neglecting PA may lead to an incorrect estimate of ta. Personalized PA should be considered in patients with Toric intraocular lens implants. Key words: posterior corneal astigmatism; high myopia; cataract
高度近视白内障患者角膜后散光的特征
目的:探讨高度近视白内障患者角膜后散光(PA)的特点。方法:本系列病例研究选取山西省眼科医院2018年1 - 6月收治的215例患者215只眼,分为高度近视组(94例,94只眼)和对照组(121例,121只眼)。采用旋转Scheimplfulg相机(Pentacam HR)测量PA、角膜总散光(TA)和模拟角膜散光(KA)。采用矢量法和算术分析法计算了KA法测温产生的误差。结果:高度近视组平均近视度数为-0.33±0.20 D,超过0.5 D的占30.8%;最陡子午线垂直排列的占79.6%。高度近视组与对照组的平均屈光度为-0.31±0.18 d,差异无统计学意义(t=0.589, P=0.557)。高度近视组KA与TA的矢量误差为(0.12±0.21)D@4°。PA与KA、PA与Km (KA)、PA与Km (PA)呈显著相关(r=0.340, P=0.001;r = 0.285, P = 0.006;r = 0.333, P = 0.001)。对于KA>0.5 D的患者,ta和KA的幅度差异随着pa幅度的增加而显著增加(r=0.235, P=0.004)。结论:高度近视组与对照组之间PA无显著性差异。在高度近视组中,忽略PA可能导致对ta的不正确估计。环形人工晶状体植入术患者应考虑个体化PA。关键词:角膜后散光;高度近视;白内障
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信