A practical and single-use ITO-PET based immunosensing platform for detection of Tumor Necrosis Factor-alpha biomarker

Burcu Özcan
{"title":"A practical and single-use ITO-PET based immunosensing platform for detection of Tumor Necrosis Factor-alpha biomarker","authors":"Burcu Özcan","doi":"10.15671/hjbc.1215813","DOIUrl":null,"url":null,"abstract":"This investigation displays a novel, practical indium tin oxide- polyethylene terephthalate (ITO-PET) based electrochemical biosensor for the Tumor Necrosis Factor-alpha (TNFα) biomarker determination. The ITO-PET electrode is a very advantageous preferred semiconductive electrode material. It has a lot of great features such as easy to prepare, cheapness, flexibility, stability. It also allows determining an analyte at very low concentrations and provides a great wide concentration range for analyte analysis. Electrochemical Impedance Spectroscopy (EIS) and Cyclic Voltammetry (CV) were used for the evaluation of biosensors, including the immobilization procedure, the investigation of the optimum conditions, and the characterization of biosensors. The immunosensor's electrode surface morphology during the immobilization process was observed using a Scanning Electron Microscope (SEM). In addition, Impedance measurement at a single frequency was used to characterize anti-TNFα and TNFα interactions (SFI). The clinical effectiveness of the developed biosensor was investigated by testing it with real human serum samples. Moreover, the fabricated immunosensor presents long shelf life, analysis of the antigen concentrations at picogram level (0.02 pg mL-1 -2.56 pg mL-1), reproducibility, reusability (11 times) and high sensitivity.","PeriodicalId":12939,"journal":{"name":"Hacettepe Journal of Biology and Chemistry","volume":"49 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-01-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hacettepe Journal of Biology and Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15671/hjbc.1215813","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This investigation displays a novel, practical indium tin oxide- polyethylene terephthalate (ITO-PET) based electrochemical biosensor for the Tumor Necrosis Factor-alpha (TNFα) biomarker determination. The ITO-PET electrode is a very advantageous preferred semiconductive electrode material. It has a lot of great features such as easy to prepare, cheapness, flexibility, stability. It also allows determining an analyte at very low concentrations and provides a great wide concentration range for analyte analysis. Electrochemical Impedance Spectroscopy (EIS) and Cyclic Voltammetry (CV) were used for the evaluation of biosensors, including the immobilization procedure, the investigation of the optimum conditions, and the characterization of biosensors. The immunosensor's electrode surface morphology during the immobilization process was observed using a Scanning Electron Microscope (SEM). In addition, Impedance measurement at a single frequency was used to characterize anti-TNFα and TNFα interactions (SFI). The clinical effectiveness of the developed biosensor was investigated by testing it with real human serum samples. Moreover, the fabricated immunosensor presents long shelf life, analysis of the antigen concentrations at picogram level (0.02 pg mL-1 -2.56 pg mL-1), reproducibility, reusability (11 times) and high sensitivity.
一个实用的、一次性的、基于ITO-PET的检测肿瘤坏死因子- α生物标志物的免疫传感平台
本研究展示了一种新型的、实用的基于氧化铟锡-聚对苯二甲酸乙二醇酯(ITO-PET)的电化学生物传感器,用于肿瘤坏死因子- α (tnf - α)生物标志物的测定。ITO-PET电极是一种非常有利的首选半导体电极材料。它具有制备简单、价格便宜、灵活、稳定等优点。它还允许在非常低的浓度下测定分析物,并为分析物分析提供了很大的浓度范围。利用电化学阻抗谱(EIS)和循环伏安法(CV)对生物传感器进行了评价,包括固定化过程、最佳条件的研究和生物传感器的表征。利用扫描电镜观察免疫传感器在固定过程中的电极表面形貌。此外,单频阻抗测量用于表征抗TNFα和TNFα相互作用(SFI)。通过对真实人血清样本的检测,考察了所研制的生物传感器的临床有效性。此外,制备的免疫传感器具有保质期长,抗原浓度分析在picogram水平(0.02 pg mL-1 -2.56 pg mL-1),重复性好,可重复使用(11次)和高灵敏度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信