Variations in Low Electrical Stimulator Voltage Settings Minimally Influence Beef Longissimus Muscle Slice Shear Force Values

T. Arp, E. Rice, D. Woerner, Kenichi Kathoh, Gary C. Smith, K. Belk, M. Nair
{"title":"Variations in Low Electrical Stimulator Voltage Settings Minimally Influence Beef Longissimus Muscle Slice Shear Force Values","authors":"T. Arp, E. Rice, D. Woerner, Kenichi Kathoh, Gary C. Smith, K. Belk, M. Nair","doi":"10.22175/mmb.12549","DOIUrl":null,"url":null,"abstract":"The objective of the current study was to evaluate the effect of differing electrical stimulation (ES) voltage levels on beef longissimus muscle tenderness, postmortem temperature, pH decline, and carcass quality. Beef carcasses from 3 commercial beef processing plants (A, B, C) were exposed to 3 varying voltage levels: (1) control (no ES), (2) ES level 1 (ES1; 60 Hz for 17 s each at 16, 20, 24, and 28 V), and (3) ES level 2 (ES2; 60 Hz for 17 s each at 25, 35, 45, and 55 V) prior to chilling. Ninety beef carcasses were selected from each of the 3 plants, and within a carcass, paired sides were randomly assigned to one of 3 ES treatments (n = 60 sides/treatment/plant). The results indicated that ES affected (P < 0.05) muscle pH at 3 h postmortem in 2 of the 3 plants. However, ES did not affect (P > 0.05) pH at the time of grading (postrigor). Although the slice shear force (SSF) values were lower (P < 0.05) for ES steaks compared with controls, voltage did not affect (P > 0.05) SSF values. Variation in SSF was observed among the plants (P < 0.05), with steaks from Plant C having greater (P < 0.05) SSF values compared with steaks from Plants A and B, which exhibited similar (P > 0.05) SSF values. Overall, although ES steaks had lower SSF values compared with control steaks, the lack of difference in postmortem tenderness between ES1 and ES2 voltage settings indicated that the low ES voltages minimally influenced SSF values.","PeriodicalId":18316,"journal":{"name":"Meat and Muscle Biology","volume":"41 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-08-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Meat and Muscle Biology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22175/mmb.12549","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The objective of the current study was to evaluate the effect of differing electrical stimulation (ES) voltage levels on beef longissimus muscle tenderness, postmortem temperature, pH decline, and carcass quality. Beef carcasses from 3 commercial beef processing plants (A, B, C) were exposed to 3 varying voltage levels: (1) control (no ES), (2) ES level 1 (ES1; 60 Hz for 17 s each at 16, 20, 24, and 28 V), and (3) ES level 2 (ES2; 60 Hz for 17 s each at 25, 35, 45, and 55 V) prior to chilling. Ninety beef carcasses were selected from each of the 3 plants, and within a carcass, paired sides were randomly assigned to one of 3 ES treatments (n = 60 sides/treatment/plant). The results indicated that ES affected (P < 0.05) muscle pH at 3 h postmortem in 2 of the 3 plants. However, ES did not affect (P > 0.05) pH at the time of grading (postrigor). Although the slice shear force (SSF) values were lower (P < 0.05) for ES steaks compared with controls, voltage did not affect (P > 0.05) SSF values. Variation in SSF was observed among the plants (P < 0.05), with steaks from Plant C having greater (P < 0.05) SSF values compared with steaks from Plants A and B, which exhibited similar (P > 0.05) SSF values. Overall, although ES steaks had lower SSF values compared with control steaks, the lack of difference in postmortem tenderness between ES1 and ES2 voltage settings indicated that the low ES voltages minimally influenced SSF values.
低电刺激器电压设置的变化对牛肉最长肌切片剪切力值的影响最小
本研究的目的是评估不同电刺激(ES)电压水平对牛肉最长肌压痛、死后温度、pH值下降和胴体质量的影响。来自3家商业牛肉加工厂(A, B, C)的牛肉尸体暴露在3个不同的电压水平下:(1)控制(无ES), (2) ES1级(ES1);60 Hz,在16、20、24和28 V电压下各17 s), (3) ES级2 (ES2;60hz,在25,35,45和55v下各17秒),然后冷却。从3个屠宰场各选择90具牛肉胴体,在每具胴体内,将配对的胴体随机分配到3个ES处理中的一个(n = 60只胴体/处理/屠宰场)。结果表明,ES对死后3 h肌肉pH有显著影响(P < 0.05)。然而,ES对分级时的pH值没有影响(P > 0.05)。虽然ES牛排的切片剪切力(SSF)值低于对照组(P < 0.05),但电压对SSF值没有影响(P < 0.05)。不同植物间SSF值存在差异(P < 0.05),其中植物C的SSF值高于植物A和植物B (P < 0.05)。总体而言,尽管ES牛排的SSF值低于对照牛排,但ES1和ES2电压设置在死后嫩度方面没有差异,这表明低ES电压对SSF值的影响最小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.50
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信