{"title":"Relative performance of spiral scan over raster scan in the AFM imaging","authors":"M. S. Rana, H. Pota, I. Petersen","doi":"10.1109/CEEE.2015.7428259","DOIUrl":null,"url":null,"abstract":"In this paper, we first consider the use of a spiral rather than the conventional raster scanning method for improving the imaging performance of an atomic force microscope (AFM). To generate spirals, single-frequency, slowly varying amplitude sine and cosine waves are applied to the X- and Y-piezos, respectively, of the piezoelectric tube scanner (PTS) of an AFM. To demonstrate the performance improvement with the spiral scanning method, a comparison of spiral and raster scanning techniques is presented. In each case, the closed-loop operation is performed using a multi-input multi-output (MIMO) model predictive control (MPC) scheme augmented with a vibration compensator to minimize the tracking error.","PeriodicalId":6490,"journal":{"name":"2015 International Conference on Electrical & Electronic Engineering (ICEEE)","volume":"21 1","pages":"217-220"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Electrical & Electronic Engineering (ICEEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEEE.2015.7428259","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this paper, we first consider the use of a spiral rather than the conventional raster scanning method for improving the imaging performance of an atomic force microscope (AFM). To generate spirals, single-frequency, slowly varying amplitude sine and cosine waves are applied to the X- and Y-piezos, respectively, of the piezoelectric tube scanner (PTS) of an AFM. To demonstrate the performance improvement with the spiral scanning method, a comparison of spiral and raster scanning techniques is presented. In each case, the closed-loop operation is performed using a multi-input multi-output (MIMO) model predictive control (MPC) scheme augmented with a vibration compensator to minimize the tracking error.
螺旋扫描与光栅扫描在AFM成像中的相对性能
在本文中,我们首先考虑使用螺旋扫描而不是传统的光栅扫描方法来改善原子力显微镜(AFM)的成像性能。为了产生螺旋,将单频、缓慢变化振幅的正弦和余弦波分别应用于AFM的压电管扫描仪(PTS)的X和y压电。为了说明螺旋扫描方法在性能上的改进,对螺旋扫描和光栅扫描技术进行了比较。在每种情况下,采用多输入多输出(MIMO)模型预测控制(MPC)方案进行闭环操作,并增加振动补偿器以最小化跟踪误差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信