Left Ventricular Function Improve after Bench Press: A Speckle Tracking and 3D Echocardiography Study

M. R. Bailén, C. Jesus
{"title":"Left Ventricular Function Improve after Bench Press: A Speckle Tracking and 3D Echocardiography Study","authors":"M. R. Bailén, C. Jesus","doi":"10.4172/2161-0673.1000186","DOIUrl":null,"url":null,"abstract":"Background: The speckle tracking echocardiography is a powerful tool that is expanding knowledge on cardiovascular physiology. At present fitness is an increasing sport, and the bench press is a typical exercise. The aim of this study was to investigate by speckle tracking echocardiography the systolic and diastolic properties of the left ventricle during bench press. Methods: Interventional study. We perform an echocardiogram before, during and immediately after a bench press. During the bench press we assessed the changes suffered in systolic and diastolic functions. Speckle tracking parameter and 3D volume were calculated for left ventricle. Results: In the study were included 59 male athletes with mean age 34.28 ± 9.54 years. Left ventricle ejection fraction is increased by 2D and 3D echocardiography (0.58 ± 0.07 versus 0.62 ± 0.07, p=0.017). The strain, strain rate, and systolic and diastolic velocities of longitudinal left ventricular fibers (by Speckle Tracking) are higher during exercise [(Strain -21.1 ± 4.09 versus -27.28 ± 3.73, p<0.01) (Strain Rate -1.48 ± 0,30 versus -2.30 ± 0.57; p<0.0001]. The E/E' ratio was unchanged but improved diastolic function improve by Speckle Tracking echocardiography. After the exercise there was more left intraventricular synchrony. Strength training degree could be associated with compliance and synchrony of left ventricle. Conclusion: During bench press a discrete increase in ejection fraction and large variations in myocardial deformation occurs. Diastolic function is unchanged by 2D echocardiography. Strength training degree could be associated with compliance and synchrony of left ventricle.","PeriodicalId":17085,"journal":{"name":"Journal of Sports Medicine & Doping Studies","volume":"83 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Sports Medicine & Doping Studies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4172/2161-0673.1000186","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The speckle tracking echocardiography is a powerful tool that is expanding knowledge on cardiovascular physiology. At present fitness is an increasing sport, and the bench press is a typical exercise. The aim of this study was to investigate by speckle tracking echocardiography the systolic and diastolic properties of the left ventricle during bench press. Methods: Interventional study. We perform an echocardiogram before, during and immediately after a bench press. During the bench press we assessed the changes suffered in systolic and diastolic functions. Speckle tracking parameter and 3D volume were calculated for left ventricle. Results: In the study were included 59 male athletes with mean age 34.28 ± 9.54 years. Left ventricle ejection fraction is increased by 2D and 3D echocardiography (0.58 ± 0.07 versus 0.62 ± 0.07, p=0.017). The strain, strain rate, and systolic and diastolic velocities of longitudinal left ventricular fibers (by Speckle Tracking) are higher during exercise [(Strain -21.1 ± 4.09 versus -27.28 ± 3.73, p<0.01) (Strain Rate -1.48 ± 0,30 versus -2.30 ± 0.57; p<0.0001]. The E/E' ratio was unchanged but improved diastolic function improve by Speckle Tracking echocardiography. After the exercise there was more left intraventricular synchrony. Strength training degree could be associated with compliance and synchrony of left ventricle. Conclusion: During bench press a discrete increase in ejection fraction and large variations in myocardial deformation occurs. Diastolic function is unchanged by 2D echocardiography. Strength training degree could be associated with compliance and synchrony of left ventricle.
卧推后左心室功能改善:斑点跟踪和三维超声心动图研究
背景:斑点跟踪超声心动图是扩展心血管生理学知识的有力工具。目前健身是一项越来越受欢迎的运动,卧推是一种典型的运动。本研究的目的是通过斑点跟踪超声心动图研究左心室在卧推时的收缩和舒张特性。方法:介入研究。我们在卧推前、卧推中、卧推后都会做超声心动图检查。在卧推期间,我们评估了收缩和舒张功能的变化。计算左心室散斑跟踪参数和三维体积。结果:纳入男性运动员59例,平均年龄34.28±9.54岁。2D和3D超声心动图显示左心室射血分数升高(0.58±0.07 vs 0.62±0.07,p=0.017)。运动时左心室纵向纤维的应变、应变率和收缩、舒张速度(斑点追踪)较高(应变-21.1±4.09比-27.28±3.73,p<0.01)(应变率-1.48±0,30比-2.30±0.57;p < 0.0001)。超声心动图显示E/E比值无变化,但舒张功能有所改善。运动后左脑室同步性增强。力量训练程度与左心室顺应性、同步性相关。结论:卧推时射血分数离散增加,心肌变形变化较大。二维超声心动图显示舒张功能未见改变。力量训练程度与左心室顺应性、同步性相关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信