Determination of lovastatin, mevastatin, rosuvastatin and simvastatin with HPLC by means of gradient elution.

S. Marais, J. D. du Preez, L. D. du Plessis, J. du Plessis, M. Gerber
{"title":"Determination of lovastatin, mevastatin, rosuvastatin and simvastatin with HPLC by means of gradient elution.","authors":"S. Marais, J. D. du Preez, L. D. du Plessis, J. du Plessis, M. Gerber","doi":"10.1691/ph.2019.8192","DOIUrl":null,"url":null,"abstract":"A novel HPLC method with UV detection was developed and validated in skin penetration (in vitro) studies to identify and quantify lovastatin, mevastatin, rosuvastatin and simvastatin. A Venusil XBP C18 (2), 150 x 4.6 mm, 5 μm column (Agela Technologies, Newark, DE) was used with gradient elution (start at 45 % acetonitrile and increase linearly to 90 % after 1 min; hold at 90 % until 6 min and then re-equilibrate at start conditions) and the mobile phase consisted of (A) Milli-Q ® water and 0.1% orthophosphoric acid, and (B) HPLC grade acetonitrile. The flow rate was set at 1 ml/min, 240 nm UV detection and an injection volume of 10 μl. Linearity was obtained over a range of 0.50-200.00 μg/ml and correlation coefficients ranging from 0.998-1.000 were obtained. Average recovery ranged from 95.9-100.6 %. The LOD and LOQ values obtained from the slope of a calibration curve and the standard deviation of the response ranged from 0.0138-0.0860 μg/ml and 0.0419-0.2615 μg/ml, respectively, where lovastatin and simvastatin could be detected at a concentration similar to the other statins, but could only be quantified at a higher concentration than the remaining statins. The specificity of the method was proved as accurate and quantification of statins was found, even within the incorporation of other compounds.","PeriodicalId":86039,"journal":{"name":"Die Pharmazie. Beihefte","volume":"32 1","pages":"658-660"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Die Pharmazie. Beihefte","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1691/ph.2019.8192","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

A novel HPLC method with UV detection was developed and validated in skin penetration (in vitro) studies to identify and quantify lovastatin, mevastatin, rosuvastatin and simvastatin. A Venusil XBP C18 (2), 150 x 4.6 mm, 5 μm column (Agela Technologies, Newark, DE) was used with gradient elution (start at 45 % acetonitrile and increase linearly to 90 % after 1 min; hold at 90 % until 6 min and then re-equilibrate at start conditions) and the mobile phase consisted of (A) Milli-Q ® water and 0.1% orthophosphoric acid, and (B) HPLC grade acetonitrile. The flow rate was set at 1 ml/min, 240 nm UV detection and an injection volume of 10 μl. Linearity was obtained over a range of 0.50-200.00 μg/ml and correlation coefficients ranging from 0.998-1.000 were obtained. Average recovery ranged from 95.9-100.6 %. The LOD and LOQ values obtained from the slope of a calibration curve and the standard deviation of the response ranged from 0.0138-0.0860 μg/ml and 0.0419-0.2615 μg/ml, respectively, where lovastatin and simvastatin could be detected at a concentration similar to the other statins, but could only be quantified at a higher concentration than the remaining statins. The specificity of the method was proved as accurate and quantification of statins was found, even within the incorporation of other compounds.
梯度洗脱HPLC法测定洛伐他汀、美伐他汀、瑞舒伐他汀和辛伐他汀的含量。
建立了一种新的紫外检测高效液相色谱方法,并在皮肤渗透(体外)研究中进行了验证,以鉴定和定量洛伐他汀、美伐他汀、瑞舒伐他汀和辛伐他汀。采用Venusil XBP C18 (2), 150 x 4.6 mm, 5 μm色谱柱(Agela Technologies, Newark, DE),梯度洗脱(从45%乙腈开始,1 min后线性增加到90%;保持90%至6分钟,然后在启动条件下重新平衡),流动相为(A) milliq®水和0.1%正磷酸,(B) HPLC级乙腈。流速为1 ml/min,紫外检测240 nm,进样量为10 μl。在0.50 ~ 200.00 μg/ml范围内呈线性关系,相关系数为0.998 ~ 1.000。平均回收率为95.9 ~ 100.6%。校正曲线斜率的定量限和定量限分别为0.0138 ~ 0.0860 μg/ml和0.0419 ~ 0.2615 μg/ml,其中洛伐他汀和辛伐他汀可以在与其他他汀类药物相似的浓度下检测到,但只能在高于其他他汀类药物的浓度下定量。该方法的特异性被证明是准确的,并且发现了他汀类药物的定量,即使在合并其他化合物的情况下。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信