{"title":"Pembuatan model alat pembuang panas untuk air pendingin alat praktikum heat exchanger merk PA Hilton seri H101 di laboratorium teknik mesin","authors":"Hadimi Hadimi, Rusadi Rusadi","doi":"10.24127/trb.v11i1.1768","DOIUrl":null,"url":null,"abstract":"Heat Exchanger Service Unit H101/08490 PA Hilton Ltd that use for heat transfer experiment has a weakness because the water flow from the unit after taking heat will directly enter the storage tank, still have a high temperature ( >33 o C ). The use of practicum equipment for a experiment with a long enough duration will cause the cooling water are used have a high temperature and be ineffective for the heat exchanger cooling process. The purpose of making a Cooling Tower Type Heat Dissipator Model for Heat Exchanger Service Unit H101/08490 PA Hilton Ltd so that the cooling water used to carry out the practicum will be maintained at a temperature of 28 o C-33 o C. Maintaining the stability of the cooling water temperature is expected to produce data that does not vary too much and can be done in a fairly long data collection range. The results of the performance and effectiveness test of Cooling Tower cooling show that the temperature increase is only 4 o C for 3 hours of testing and the cooling effectiveness increases and is relatively constant during the test time. This shows that the cooling system with a Cooling Tower can be used as a supporting medium for heat exchanger practicum in the Mechanical Engineering department.","PeriodicalId":31503,"journal":{"name":"Turbo Jurnal Program Studi Teknik Mesin","volume":"15 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turbo Jurnal Program Studi Teknik Mesin","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24127/trb.v11i1.1768","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Heat Exchanger Service Unit H101/08490 PA Hilton Ltd that use for heat transfer experiment has a weakness because the water flow from the unit after taking heat will directly enter the storage tank, still have a high temperature ( >33 o C ). The use of practicum equipment for a experiment with a long enough duration will cause the cooling water are used have a high temperature and be ineffective for the heat exchanger cooling process. The purpose of making a Cooling Tower Type Heat Dissipator Model for Heat Exchanger Service Unit H101/08490 PA Hilton Ltd so that the cooling water used to carry out the practicum will be maintained at a temperature of 28 o C-33 o C. Maintaining the stability of the cooling water temperature is expected to produce data that does not vary too much and can be done in a fairly long data collection range. The results of the performance and effectiveness test of Cooling Tower cooling show that the temperature increase is only 4 o C for 3 hours of testing and the cooling effectiveness increases and is relatively constant during the test time. This shows that the cooling system with a Cooling Tower can be used as a supporting medium for heat exchanger practicum in the Mechanical Engineering department.