Harmonizing ventilation requirements for indoor lighter than air hazardous atmospheres

Troy Rains, Bipin Satavalekar
{"title":"Harmonizing ventilation requirements for indoor lighter than air hazardous atmospheres","authors":"Troy Rains, Bipin Satavalekar","doi":"10.1109/PCIC.2010.5666865","DOIUrl":null,"url":null,"abstract":"This paper compares the major concepts in ventilation requirements contained in API RP 500/505 and IEC 60079–10, specific to indoor, lighter than air, natural gas hazardous atmospheres. Engineering professionals rely on API 505 as the basis for area classifications. Previously, IEC and North American standards have been successfully adopted in the body of API 500/505 (79–10 Mod). However, the informative appendices of both standards covering ventilation calculations are not entirely consistent. This paper presents case studies for ventilation/classification and an attempt is made to harmonize ventilation calculations to offer further uniformity in global standards. This will be of interest to those involved with area classification activities, as the result may offer reduced mechanical ventilation demands, while maintaining equivalent levels of safety and reliability.","PeriodicalId":67291,"journal":{"name":"中国石油和化工(企业版)","volume":"47 1","pages":"1-9"},"PeriodicalIF":0.0000,"publicationDate":"2010-12-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国石油和化工(企业版)","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.1109/PCIC.2010.5666865","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

This paper compares the major concepts in ventilation requirements contained in API RP 500/505 and IEC 60079–10, specific to indoor, lighter than air, natural gas hazardous atmospheres. Engineering professionals rely on API 505 as the basis for area classifications. Previously, IEC and North American standards have been successfully adopted in the body of API 500/505 (79–10 Mod). However, the informative appendices of both standards covering ventilation calculations are not entirely consistent. This paper presents case studies for ventilation/classification and an attempt is made to harmonize ventilation calculations to offer further uniformity in global standards. This will be of interest to those involved with area classification activities, as the result may offer reduced mechanical ventilation demands, while maintaining equivalent levels of safety and reliability.
协调室内比空气轻的危险环境的通风要求
本文比较了API RP 500/505和IEC 60079-10中通风要求的主要概念,具体到室内,比空气轻,天然气危险环境。工程专业人员依靠API 505作为区域分类的基础。此前,IEC和北美标准已成功地应用于API 500/505 (79-10 Mod)的主体。然而,两个标准的信息附录涵盖通风计算并不完全一致。本文介绍了通风/分类的案例研究,并试图协调通风计算,以进一步统一全球标准。这将引起参与区域分类活动的人员的兴趣,因为结果可能会减少机械通风需求,同时保持同等水平的安全性和可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
346
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书