Auditory neuropathy spectrum disorder: Examples of poor progress following cochlear implantation

W. Neary, G. Lightfoot
{"title":"Auditory neuropathy spectrum disorder: Examples of poor progress following cochlear implantation","authors":"W. Neary, G. Lightfoot","doi":"10.3109/1651386X.2012.707352","DOIUrl":null,"url":null,"abstract":"Abstract The majority of babies with auditory neuropathy spectrum disorder (ANSD) spend 48 h or more in the Special Care Baby Unit (SCBU), and the current UK recommendations for the Newborn Hearing Screening Programme state that babies admitted to the SCBU should undergo hearing screening with transient evoked otoacoustic emissions together with automated auditory brainstem response audiometry, in order to identify babies affected with the condition. Current recommendations propose that individuals affected with ANSD should be considered candidates for cochlear implantation. It has been suggested that in patients with ANSD, the presence or absence of cortical electric response audiometry (CERA) responses can help to predict favourable or unfavourable prognosis in auditory language development and comprehension post implantation. We describe two individuals who had not been in SCBU, but came from the well baby population yet satisfied the diagnostic criteria for ANSD. These two patients underwent cochlear implantation, but made poor progress in auditory language development and speech understanding on subsequent follow-up. We suggest that ANSD should be considered in all cases of infants who undergo cochlear implantation but do not make subsequent good progress in auditory language development and speech understanding. We further suggest that CERA be performed prior to cochlear implantation in patients satisfying the diagnostic criteria for ANSD, as the results can assist in predicting post implantation progress in auditory language development and speech understanding.","PeriodicalId":88223,"journal":{"name":"Audiological medicine","volume":"29 1","pages":"143 - 150"},"PeriodicalIF":0.0000,"publicationDate":"2012-08-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Audiological medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/1651386X.2012.707352","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

Abstract The majority of babies with auditory neuropathy spectrum disorder (ANSD) spend 48 h or more in the Special Care Baby Unit (SCBU), and the current UK recommendations for the Newborn Hearing Screening Programme state that babies admitted to the SCBU should undergo hearing screening with transient evoked otoacoustic emissions together with automated auditory brainstem response audiometry, in order to identify babies affected with the condition. Current recommendations propose that individuals affected with ANSD should be considered candidates for cochlear implantation. It has been suggested that in patients with ANSD, the presence or absence of cortical electric response audiometry (CERA) responses can help to predict favourable or unfavourable prognosis in auditory language development and comprehension post implantation. We describe two individuals who had not been in SCBU, but came from the well baby population yet satisfied the diagnostic criteria for ANSD. These two patients underwent cochlear implantation, but made poor progress in auditory language development and speech understanding on subsequent follow-up. We suggest that ANSD should be considered in all cases of infants who undergo cochlear implantation but do not make subsequent good progress in auditory language development and speech understanding. We further suggest that CERA be performed prior to cochlear implantation in patients satisfying the diagnostic criteria for ANSD, as the results can assist in predicting post implantation progress in auditory language development and speech understanding.
听神经病变谱系障碍:人工耳蜗植入后不良进展的例子
大多数患有听觉神经病变谱系障碍(ANSD)的婴儿在特殊护理婴儿病房(SCBU)度过48小时或更长时间,目前英国对新生儿听力筛查计划的建议指出,入住SCBU的婴儿应接受瞬态诱发耳声发射和自动听觉脑干反应听力学的听力筛查,以识别受该病症影响的婴儿。目前的建议建议,受ANSD影响的个体应考虑人工耳蜗植入术的候选人。研究表明,在ANSD患者中,皮质电反应听力学(CERA)反应的存在与否可以帮助预测植入后听觉语言发育和理解的预后好坏。我们描述了两个没有在SCBU的个体,但来自健康的婴儿群体,但满足了ANSD的诊断标准。这2例患者接受了人工耳蜗植入,但在后续随访中,听觉语言发展和言语理解进展不佳。我们建议在所有接受人工耳蜗植入但在听觉语言发展和言语理解方面没有取得良好进展的婴儿中都应考虑ANSD。我们进一步建议在符合ANSD诊断标准的患者植入人工耳蜗之前进行CERA,因为结果可以帮助预测植入后听觉语言发育和言语理解的进展。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信