A. Gosar, R. Phadke, Deepesh Patil, K. Gupta, P. Thakur
{"title":"Development and Validation of an New High Performance Liquid Chromatography Method for Determination of Apixaban Isomers","authors":"A. Gosar, R. Phadke, Deepesh Patil, K. Gupta, P. Thakur","doi":"10.11648/J.CBE.20200501.11","DOIUrl":null,"url":null,"abstract":"The purpose of this research study is to develop a novel, simple, precise, accurate and economical method for determination of Apixaban API isomers. Apixaban API has three isomer as ortho, meta and para. In reverse phase and normal phase chromatography it was very difficult to separate these isomer; hence new chiral technique was adopted. This chromatographic method was developed on chiralpak IA column (250×4.6×5µm) with isocritic technique. The detection of isomeric impurities were observed at wavelength 290nm. This analytical method was validated as per ICH guideline and regression analysis showed R value (correlation coefficient) > 0.999 for Apixaban API and its isomeric impurities. A solution of Apixaban in dichloromethane was found stable up to 48 hrs. The degradation study was done within the given guidelines prescribed by ICH. The method is validated for Linearity, Accuracy and Precision.","PeriodicalId":8234,"journal":{"name":"Annual review of chemical and biomolecular engineering","volume":"7 1","pages":""},"PeriodicalIF":7.6000,"publicationDate":"2020-01-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annual review of chemical and biomolecular engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.11648/J.CBE.20200501.11","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, APPLIED","Score":null,"Total":0}
引用次数: 1
Abstract
The purpose of this research study is to develop a novel, simple, precise, accurate and economical method for determination of Apixaban API isomers. Apixaban API has three isomer as ortho, meta and para. In reverse phase and normal phase chromatography it was very difficult to separate these isomer; hence new chiral technique was adopted. This chromatographic method was developed on chiralpak IA column (250×4.6×5µm) with isocritic technique. The detection of isomeric impurities were observed at wavelength 290nm. This analytical method was validated as per ICH guideline and regression analysis showed R value (correlation coefficient) > 0.999 for Apixaban API and its isomeric impurities. A solution of Apixaban in dichloromethane was found stable up to 48 hrs. The degradation study was done within the given guidelines prescribed by ICH. The method is validated for Linearity, Accuracy and Precision.
期刊介绍:
The Annual Review of Chemical and Biomolecular Engineering aims to provide a perspective on the broad field of chemical (and related) engineering. The journal draws from disciplines as diverse as biology, physics, and engineering, with development of chemical products and processes as the unifying theme.