The Efficiency of Applying the Radiology Technologist of the Radiation Dose Monitoring Technique During the Fluoroscopy Procedures for Oncology in Paediatrics Care Aged Between 4 to 7 Years

Hissa Mohammed
{"title":"The Efficiency of Applying the Radiology Technologist of the Radiation Dose Monitoring Technique During the Fluoroscopy Procedures for Oncology in Paediatrics Care Aged Between 4 to 7 Years","authors":"Hissa Mohammed","doi":"10.4172/2155-9937.1000140","DOIUrl":null,"url":null,"abstract":"Fluoroscopy is one of the radiation sources used in diagnostic processes in radiology. Owing to the diagnostic approach that entails observation of the affected anatomy using radiation in real time, harmful effects may potentially occur. Therefore, safety measures in the radiographer's use of equipment and effective monitoring and management are essential in diagnostic processes. Additionally, patients in the age group of four to seven years have less anatomy and tissue development, which presents higher levels of health risks. The study will focus on analyzing the pre-procedure requirements and the set of guidelines, which enable the enforcement of the safety of the concerned patients within the paediatric practice. For example, the study will observe the potency of undertaking the reduction of the fluoroscopic times and improving the communications between the health specialists. The study will also evaluate methods and techniques employed in achieving efficiency in fluoroscopy radiation dose management. Direct and indirect methods will be employed to monitor the dosage effects. Direct methods would entail performing a skin dose test on the target area of fluoroscopic radiation. Detectors would be employed, for example the photographic films and thermo-luminescent dosimeters. The indirect methods will employ the use of the dose area product meter to ascertain the effects of radiation on the patients. Some of the dose reduction techniques involve the manipulation of equipment operation, for example beam quality adjustment, dose level setting, and dose spreading. The results used to evaluate the dosage level will entail analyzing measurements of the skin exposure unit of the fluoroscopic equipment. These results will be achieved through the use of different operational voltage levels on the fluoroscopic equipment. Skin dose will be determined through a combination of several measurable factors in fluoroscopic equipment operation.","PeriodicalId":89157,"journal":{"name":"International journal of molecular imaging","volume":"25 1","pages":"1-2"},"PeriodicalIF":0.0000,"publicationDate":"2017-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of molecular imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4172/2155-9937.1000140","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Fluoroscopy is one of the radiation sources used in diagnostic processes in radiology. Owing to the diagnostic approach that entails observation of the affected anatomy using radiation in real time, harmful effects may potentially occur. Therefore, safety measures in the radiographer's use of equipment and effective monitoring and management are essential in diagnostic processes. Additionally, patients in the age group of four to seven years have less anatomy and tissue development, which presents higher levels of health risks. The study will focus on analyzing the pre-procedure requirements and the set of guidelines, which enable the enforcement of the safety of the concerned patients within the paediatric practice. For example, the study will observe the potency of undertaking the reduction of the fluoroscopic times and improving the communications between the health specialists. The study will also evaluate methods and techniques employed in achieving efficiency in fluoroscopy radiation dose management. Direct and indirect methods will be employed to monitor the dosage effects. Direct methods would entail performing a skin dose test on the target area of fluoroscopic radiation. Detectors would be employed, for example the photographic films and thermo-luminescent dosimeters. The indirect methods will employ the use of the dose area product meter to ascertain the effects of radiation on the patients. Some of the dose reduction techniques involve the manipulation of equipment operation, for example beam quality adjustment, dose level setting, and dose spreading. The results used to evaluate the dosage level will entail analyzing measurements of the skin exposure unit of the fluoroscopic equipment. These results will be achieved through the use of different operational voltage levels on the fluoroscopic equipment. Skin dose will be determined through a combination of several measurable factors in fluoroscopic equipment operation.
4 ~ 7岁儿科肿瘤透视检查中放射技师应用放射剂量监测技术的效果
透视是放射学诊断过程中使用的辐射源之一。由于诊断方法需要使用实时辐射观察受影响的解剖结构,可能会产生有害的影响。因此,在诊断过程中,放射技师使用设备的安全措施以及有效的监测和管理是必不可少的。此外,4至7岁年龄组的患者解剖和组织发育较差,这带来了更高的健康风险。这项研究的重点是分析手术前的规定和一套指导方针,以便在儿科实践中执行有关患者的安全。例如,该研究将观察减少透视时间和改善卫生专家之间沟通的效力。该研究还将评估在实现透视辐射剂量管理效率方面所采用的方法和技术。将采用直接法和间接法监测剂量效应。直接方法需要在透视辐射的靶区进行皮肤剂量试验。将使用探测器,例如照相胶片和热发光剂量计。间接方法将使用剂量面积积计来确定辐射对患者的影响。一些剂量减少技术涉及对设备操作的操纵,例如光束质量调整、剂量水平设置和剂量扩散。用于评估剂量水平的结果将需要分析透视设备的皮肤暴露单元的测量值。这些结果将通过在透视设备上使用不同的操作电压水平来实现。皮肤剂量将通过透视设备操作中几个可测量因素的组合来确定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书