{"title":"DC- Link Voltage Equalization and Second Ripple Suppression Control Strategy for Three-Phase To Single-Phase Converters","authors":"Zhiyong Qu, Jing Lin, Xiaoqiong He","doi":"10.1109/ITECAsia-Pacific56316.2022.9942159","DOIUrl":null,"url":null,"abstract":"The three-phase to single-phase three-level converter is the core equipment in the advanced traction power supply system. The voltage equalization and second ripple on the dc-link are not conducive to not only distorting the three-phase grid side current and the inverter output voltage, but also leading to the degradation of the life of the power electronic converter devices. In this paper, a three-phase to single-phase three-level converter topology based on a symmetrical half-bridge active power decoupling circuit is proposed. This structure can maintain the balance of the two voltages on the dc-link and decouple the ripple power, thereby ensuring the instantaneous power flow balance between the three-phase grid side and the half-bridge decoupling circuit and the load, and can greatly reduce the number of required passive components and volume. In order to achieve proper closed-loop regulation, a unified coordinated control strategy for voltage equalization and second ripple is proposed.","PeriodicalId":45126,"journal":{"name":"Asia-Pacific Journal-Japan Focus","volume":"9 1","pages":"1-6"},"PeriodicalIF":0.2000,"publicationDate":"2022-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asia-Pacific Journal-Japan Focus","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ITECAsia-Pacific56316.2022.9942159","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"AREA STUDIES","Score":null,"Total":0}
引用次数: 0
Abstract
The three-phase to single-phase three-level converter is the core equipment in the advanced traction power supply system. The voltage equalization and second ripple on the dc-link are not conducive to not only distorting the three-phase grid side current and the inverter output voltage, but also leading to the degradation of the life of the power electronic converter devices. In this paper, a three-phase to single-phase three-level converter topology based on a symmetrical half-bridge active power decoupling circuit is proposed. This structure can maintain the balance of the two voltages on the dc-link and decouple the ripple power, thereby ensuring the instantaneous power flow balance between the three-phase grid side and the half-bridge decoupling circuit and the load, and can greatly reduce the number of required passive components and volume. In order to achieve proper closed-loop regulation, a unified coordinated control strategy for voltage equalization and second ripple is proposed.