{"title":"The right ventricular outflow tract as an unusual location for an implantable defibrillator electrode in a patient with arrhythmogenic right ventricular dysplasia.","authors":"K. Matsuo, T. Kurita, M. Eguchi, K. Nakao, N. Komiya, H. Kawano, S. Isomoto, G. Toda, M. Hayano, K. Yano","doi":"10.1253/JCJ.65.994","DOIUrl":null,"url":null,"abstract":"A 41-year-old woman with arrhythmogenic right ventricular dysplasia (ARVD) underwent the implantation of an implantable cardioverter-defibrillator (ICD), in which the defibrillator electrode was unusually located in the right ventricular (RV) outflow tract. Although fractionated electrograms were demonstrated in the RV apex, which is the usual site for ICD electrodes, normal electrograms were recorded in the RV outflow tract during an electrophysiologic study. An electrode with a screw-in tip was used to fix the implant in the RV outflow tract and obtain successful defibrillation. If normal electrograms are recorded in the RV outflow tract, the site may prove to be an alternative location for an ICD electrode even for ARVD patients.","PeriodicalId":14544,"journal":{"name":"Japanese circulation journal","volume":"42 1","pages":"994-6"},"PeriodicalIF":0.0000,"publicationDate":"2001-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Japanese circulation journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1253/JCJ.65.994","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

A 41-year-old woman with arrhythmogenic right ventricular dysplasia (ARVD) underwent the implantation of an implantable cardioverter-defibrillator (ICD), in which the defibrillator electrode was unusually located in the right ventricular (RV) outflow tract. Although fractionated electrograms were demonstrated in the RV apex, which is the usual site for ICD electrodes, normal electrograms were recorded in the RV outflow tract during an electrophysiologic study. An electrode with a screw-in tip was used to fix the implant in the RV outflow tract and obtain successful defibrillation. If normal electrograms are recorded in the RV outflow tract, the site may prove to be an alternative location for an ICD electrode even for ARVD patients.
在致心律失常的右心室发育不良患者中,右心室流出道作为植入式除颤器电极的不寻常位置。
一例患有心律失常性右心室发育不良(ARVD)的41岁女性接受了植入式心律转复除颤器(ICD)的植入,其中除颤器电极异常地位于右心室(RV)出口道。虽然在ICD电极的通常位置右心室尖部显示了分异的电图,但在电生理学研究中,在右心室流出道记录了正常的电图。使用螺旋头电极将植入物固定在右心室流出道并成功除颤。如果在右心室流出道记录到正常的电图,那么即使对于ARVD患者,该部位也可能被证明是ICD电极的替代位置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信