{"title":"Error source determination of a magnetoresistive active power sensor at industrial frequencies","authors":"V. Vountesmeri, J. R. Cuevas, R. Carranza","doi":"10.1109/IMTC.2001.928867","DOIUrl":null,"url":null,"abstract":"The results of the experimental investigation of the error sources of a magnetoresistive active power sensor at the industrial frequency of 60 Hz are presented. The investigation has been carried out at 120 V and 1, 5, and 10 A with the aid of a power calibrator. The current and phase shift in this experiment was held to within 30 ppm and the voltage was held to within 9 ppm, respectively. The main sources of the uncertainties are phase uncertainty of the voltage divider, self-detection of the voltage and current signal, thermoelectricity, nonlinearity of the volt-watt characteristic and the temperature instability. The total uncertainty of the magnetoresistive active power sensor does not exceed 0.2%.","PeriodicalId":68878,"journal":{"name":"Journal of Measurement Science and Instrumentation","volume":"90 1","pages":"490-492 vol.1"},"PeriodicalIF":0.0000,"publicationDate":"2001-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Measurement Science and Instrumentation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMTC.2001.928867","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
The results of the experimental investigation of the error sources of a magnetoresistive active power sensor at the industrial frequency of 60 Hz are presented. The investigation has been carried out at 120 V and 1, 5, and 10 A with the aid of a power calibrator. The current and phase shift in this experiment was held to within 30 ppm and the voltage was held to within 9 ppm, respectively. The main sources of the uncertainties are phase uncertainty of the voltage divider, self-detection of the voltage and current signal, thermoelectricity, nonlinearity of the volt-watt characteristic and the temperature instability. The total uncertainty of the magnetoresistive active power sensor does not exceed 0.2%.