{"title":"The effect of contact time between alginate impression material and type III dental stone on the surface properties of stone casts","authors":"S. Dulaimi, Atyaf M Alnaser, Najwah Y Hameed","doi":"10.26477/jbcd.v33i3.2949","DOIUrl":null,"url":null,"abstract":"Background: Alginate impression material is the irreversible hydrocolloid material that is widely used in dentistry. The contact time between alginate and gypsum cast could have a detrimental effect on the properties of the gypsum cast. The objective of this study is to evaluate the impact of various contact time intervals of Alginate impressions & type III dental stone on surface properties of stone cast. Materials and Methods: Time intervals tested were 1hour, 6 hours and 9 hours. Surface properties of stone cast evaluated were surface detail reproduction, hardness and roughness. Surface detail reproduction was determined using cylindrical brass test block in accordance with ISO 1563. Surface roughness was measured by profilometer and hardness was measured by Durometer (Shore D). Results: The detail reproduction showed significant difference (P<0.05), at 6 hr., and 9 hr. showed better results. While surface roughness significantly decreased (p<0.01) with prolonged contact time. However, surface hardness increased significantly (p<0.01) with increased contact time. Conclusions: Surface detail reproduction increased with increasing the contact time and this was noticed at (6, 9 hours). However, 1hour time interval showed decreased surface detailed reproduction. Roughness decreased when the contact time was increased between type III dental stone and alginate impression whereas, hardness was improved significantly with increasing contact time.","PeriodicalId":15041,"journal":{"name":"Journal of baghdad college of dentistry","volume":"234 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of baghdad college of dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26477/jbcd.v33i3.2949","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Alginate impression material is the irreversible hydrocolloid material that is widely used in dentistry. The contact time between alginate and gypsum cast could have a detrimental effect on the properties of the gypsum cast. The objective of this study is to evaluate the impact of various contact time intervals of Alginate impressions & type III dental stone on surface properties of stone cast. Materials and Methods: Time intervals tested were 1hour, 6 hours and 9 hours. Surface properties of stone cast evaluated were surface detail reproduction, hardness and roughness. Surface detail reproduction was determined using cylindrical brass test block in accordance with ISO 1563. Surface roughness was measured by profilometer and hardness was measured by Durometer (Shore D). Results: The detail reproduction showed significant difference (P<0.05), at 6 hr., and 9 hr. showed better results. While surface roughness significantly decreased (p<0.01) with prolonged contact time. However, surface hardness increased significantly (p<0.01) with increased contact time. Conclusions: Surface detail reproduction increased with increasing the contact time and this was noticed at (6, 9 hours). However, 1hour time interval showed decreased surface detailed reproduction. Roughness decreased when the contact time was increased between type III dental stone and alginate impression whereas, hardness was improved significantly with increasing contact time.
海藻酸盐印模材料与III型牙石接触时间对牙石铸型表面性能的影响
背景:藻酸盐印模材料是一种不可逆的水胶体材料,广泛应用于牙科。海藻酸盐与石膏模的接触时间对石膏模的性能有不利的影响。本研究的目的是评估海藻酸盐印模和III型牙石的不同接触时间间隔对铸石表面性能的影响。材料与方法:试验时间间隔为1h、6h、9h。评估了铸石的表面性能,包括表面细节再现、硬度和粗糙度。表面细节再现是根据ISO 1563使用圆柱形黄铜测试块确定的。用轮廓仪测量表面粗糙度,用硬度仪测量硬度(Shore D)。结果:在6小时时,细节再现有显著差异(P<0.05)。9小时。结果更好。表面粗糙度随接触时间延长而显著降低(p<0.01)。表面硬度随接触时间的增加而显著升高(p<0.01)。结论:表面细节再现随着接触时间的增加而增加,这在(6,9小时)时被注意到。但时间间隔1小时,表面细节再现下降。III型牙石与藻酸盐印模接触时间越长,其粗糙度降低,硬度随接触时间的增加而显著提高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.00
自引率
0.00%
发文量
0
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书