Setting up an own laboratory performance-based internal quality control plan - a model for complete blood count

IF 0.5 4区 医学 Q4 MEDICINE, RESEARCH & EXPERIMENTAL
O. Oprea, Elena Cristina Preda, I. Mănescu, M. Dobreanu
{"title":"Setting up an own laboratory performance-based internal quality control plan - a model for complete blood count","authors":"O. Oprea, Elena Cristina Preda, I. Mănescu, M. Dobreanu","doi":"10.2478/rrlm-2022-0036","DOIUrl":null,"url":null,"abstract":"Abstract Quality Control (QC) in Romania is regulated by the Order of the Minister of Health no. 1608/2022 that modifies the previous Order 1301/2007. The new version of the Order introduces a more scientific approach by requesting the laboratories to assess test performance and then elaborate an appropriate internal QC plan. The aim of this study was to demonstrate how to design a QC plan for complete blood count (CBC) in an Emergency Laboratory with continuous activity, in order to comply with the new Order 1608/2022. QC data obtained over a three-month period (April-June 2022) from the Sysmex XN-1000 instrument of the Emergency Laboratory of the County Emergency Clinical Hospital of Târgu Mureș were included. In order to establish an appropriate QC plan, two models were applied and the following parameters were calculated: the number of daily QC runs (N), the probability of false rejection (Pfr), the QC frequency (run size), and the required QC rules. White blood cells achieved high performance, while Hematocrit performance was poor. Different levels of performance were achieved for Platelets. We emphasize that, when all parameters are measured on the same instrument, QC frequency and Pfr should be adjusted in order to develop a QC plan that “fits” all the parameters of the CBC as a whole. In our Emergency Laboratory, the calculated QC plan for CBC is N=2, Pfr=0.03, multi-rule 1:3s/2:2s/R:4s, and a run size of 95 samples which is approximately the same as the number of CBCs performed during one 12-hour shift.","PeriodicalId":49599,"journal":{"name":"Revista Romana De Medicina De Laborator","volume":"1 1","pages":"477 - 482"},"PeriodicalIF":0.5000,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Romana De Medicina De Laborator","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2478/rrlm-2022-0036","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 3

Abstract

Abstract Quality Control (QC) in Romania is regulated by the Order of the Minister of Health no. 1608/2022 that modifies the previous Order 1301/2007. The new version of the Order introduces a more scientific approach by requesting the laboratories to assess test performance and then elaborate an appropriate internal QC plan. The aim of this study was to demonstrate how to design a QC plan for complete blood count (CBC) in an Emergency Laboratory with continuous activity, in order to comply with the new Order 1608/2022. QC data obtained over a three-month period (April-June 2022) from the Sysmex XN-1000 instrument of the Emergency Laboratory of the County Emergency Clinical Hospital of Târgu Mureș were included. In order to establish an appropriate QC plan, two models were applied and the following parameters were calculated: the number of daily QC runs (N), the probability of false rejection (Pfr), the QC frequency (run size), and the required QC rules. White blood cells achieved high performance, while Hematocrit performance was poor. Different levels of performance were achieved for Platelets. We emphasize that, when all parameters are measured on the same instrument, QC frequency and Pfr should be adjusted in order to develop a QC plan that “fits” all the parameters of the CBC as a whole. In our Emergency Laboratory, the calculated QC plan for CBC is N=2, Pfr=0.03, multi-rule 1:3s/2:2s/R:4s, and a run size of 95 samples which is approximately the same as the number of CBCs performed during one 12-hour shift.
建立基于实验室绩效的内部质量控制计划——全血细胞计数模型
摘要罗马尼亚的质量控制(QC)是由卫生部长令第618号规定的。第1608/2022号命令,修改了先前的第1301/2007号命令。新版本的命令引入了一种更科学的方法,要求实验室评估测试性能,然后制定适当的内部质量控制计划。本研究的目的是演示如何在持续活动的应急实验室中设计全血细胞计数(CBC)的QC计划,以符合新命令1608/2022。纳入了三个月期间(2022年4月至6月)从雷涅斯县急诊临床医院急诊实验室Sysmex XN-1000仪器获得的质量控制数据。为了制定合适的QC计划,应用了两个模型,并计算了以下参数:每日QC运行次数(N)、误拒概率(Pfr)、QC频率(运行规模)和所需的QC规则。白细胞表现良好,而红细胞压积表现较差。血小板达到了不同水平的表现。我们强调,当在同一仪器上测量所有参数时,应该调整QC频率和Pfr,以制定一个“适合”CBC所有参数的QC计划。在我们的应急实验室,计算出的全血细胞计数的QC计划为N=2, Pfr=0.03,多规则1:3s/2:2s/R:4s,运行规模为95个样本,与一个12小时轮班的全血细胞计数数量大致相同。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Revista Romana De Medicina De Laborator
Revista Romana De Medicina De Laborator MEDICINE, RESEARCH & EXPERIMENTAL-
CiteScore
0.31
自引率
20.00%
发文量
43
审稿时长
>12 weeks
期刊介绍: The aim of the journal is to publish new information that would lead to a better understanding of biological mechanisms of production of human diseases, their prevention and diagnosis as early as possible and to monitor therapy and the development of the health of patients
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信