Xinyu Gong, Yujia Chen, Guang Yu, Ni Wang, Wencheng Hu
{"title":"Multi-scan cyclic voltammetry to roughen the surface of copper foil for application in copper-clad laminates","authors":"Xinyu Gong, Yujia Chen, Guang Yu, Ni Wang, Wencheng Hu","doi":"10.1080/00202967.2023.2228078","DOIUrl":null,"url":null,"abstract":"ABSTRACT\n Multi-scan cyclic voltammetry is proposed to prepare copper foils with a matte side for use in copper-clad laminates (CCLs). During multi-scan cyclic voltammetry at −1 V ∼ 0.5 V at 80°C, the shiny side of electrolytic copper foil was subjected to zinc deposition, zinc–copper interdiffusion (alloying), and zinc dissolution (de-alloying) processes. After 21 CV cycles (315 s), small islands with a height range of 0.5∼2 μm and irregular voids formed on the matte side of the copper foil. The prepared copper foil had a specific surface area of 2.39 m2 g−1 as measured by N2 adsorption and desorption, which is greater than that of commercial copper foil with a matte side. When the copper foil was laminated as CCL, the prepared CCL had an average peel strength of 1.92 N mm−1, indicating that this route could be used for high-performance CCLs.","PeriodicalId":23251,"journal":{"name":"Transactions of the IMF","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transactions of the IMF","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/00202967.2023.2228078","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
ABSTRACT
Multi-scan cyclic voltammetry is proposed to prepare copper foils with a matte side for use in copper-clad laminates (CCLs). During multi-scan cyclic voltammetry at −1 V ∼ 0.5 V at 80°C, the shiny side of electrolytic copper foil was subjected to zinc deposition, zinc–copper interdiffusion (alloying), and zinc dissolution (de-alloying) processes. After 21 CV cycles (315 s), small islands with a height range of 0.5∼2 μm and irregular voids formed on the matte side of the copper foil. The prepared copper foil had a specific surface area of 2.39 m2 g−1 as measured by N2 adsorption and desorption, which is greater than that of commercial copper foil with a matte side. When the copper foil was laminated as CCL, the prepared CCL had an average peel strength of 1.92 N mm−1, indicating that this route could be used for high-performance CCLs.