{"title":"Hygrothermal performance of cool roofs with reflective coating material subjected to hot, humid and dusty climate","authors":"H. Saber","doi":"10.1177/17442591211001408","DOIUrl":null,"url":null,"abstract":"The measurements for the short-wave solar reflectivity of a Reflective Coating Material (RCM) with various cleaning operations that were obtained in a previous study were used in this study to conduct numerical simulations in order to assess the moisture and energy performance of cool and black roofs when they were subjected to the weather conditions of Saudi Eastern Province and Kuwait City. The results of the numerical simulations showed that black roofs always work with less moisture than cool roofs. Because the highest relative humidity in the different components of the black and cool roofs was well below 80%, there was no risk of condensation and mold growth in these roofs. For both weather conditions of Saudi Eastern Province and Kuwait City, the results showed that installing cool roofs have resulted in increasing the heating energy loads in relation to black roofs. Conversely, the results showed that the decrease in the cooling energy loads due to installing cool roofs were typically much greater than the increase in the heating energy loads. As such, cool roofs have resulted in net energy savings in relation to black roofs. Replacing black roof by cool roof in Saudi climate, the results showed that the annual energy savings in the total energy load was 25% and 34% as a result of installing cool roof with RCM at no cleaning and weekly homemade cleaning, respectively. Additionally, replacing black roof by cool roof in Kuwaiti climate, the results showed that the annual energy savings in the total energy load was 23% and 31% a result of installing cool roof with RCM at no cleaning and weekly homemade cleaning, respectively.","PeriodicalId":50249,"journal":{"name":"Journal of Building Physics","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2021-04-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Building Physics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/17442591211001408","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 5

Abstract

The measurements for the short-wave solar reflectivity of a Reflective Coating Material (RCM) with various cleaning operations that were obtained in a previous study were used in this study to conduct numerical simulations in order to assess the moisture and energy performance of cool and black roofs when they were subjected to the weather conditions of Saudi Eastern Province and Kuwait City. The results of the numerical simulations showed that black roofs always work with less moisture than cool roofs. Because the highest relative humidity in the different components of the black and cool roofs was well below 80%, there was no risk of condensation and mold growth in these roofs. For both weather conditions of Saudi Eastern Province and Kuwait City, the results showed that installing cool roofs have resulted in increasing the heating energy loads in relation to black roofs. Conversely, the results showed that the decrease in the cooling energy loads due to installing cool roofs were typically much greater than the increase in the heating energy loads. As such, cool roofs have resulted in net energy savings in relation to black roofs. Replacing black roof by cool roof in Saudi climate, the results showed that the annual energy savings in the total energy load was 25% and 34% as a result of installing cool roof with RCM at no cleaning and weekly homemade cleaning, respectively. Additionally, replacing black roof by cool roof in Kuwaiti climate, the results showed that the annual energy savings in the total energy load was 23% and 31% a result of installing cool roof with RCM at no cleaning and weekly homemade cleaning, respectively.
热、湿、多尘气候下反射涂层冷屋顶的湿热性能
在本研究中使用了在先前的研究中获得的反射涂层材料(RCM)的各种清洁操作的短波太阳反射率的测量值来进行数值模拟,以评估冷屋顶和黑色屋顶在沙特东部省和科威特市的天气条件下的水分和能源性能。数值模拟结果表明,黑色屋面在较低湿度条件下工作。由于黑色和凉爽屋顶的不同组成部分的最高相对湿度远低于80%,因此这些屋顶没有凝结和霉菌生长的风险。对于沙特东部省和科威特市的两种天气条件,结果表明,安装冷屋顶导致了相对于黑色屋顶增加的热能负荷。相反,结果表明,由于安装冷屋顶,冷却能量负荷的减少通常远大于加热能量负荷的增加。因此,与黑色屋顶相比,冷屋顶节省了净能源。在沙特气候条件下,用冷屋顶代替黑色屋顶,结果表明,在不清洁和每周自制清洁的情况下,安装带有RCM的冷屋顶,每年的总能源负荷节能分别为25%和34%。此外,在科威特气候条件下,用冷屋顶代替黑色屋顶,结果表明,在不清洁和每周自制清洁的情况下,安装带有RCM的冷屋顶,每年的总能源负荷节能分别为23%和31%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Building Physics
Journal of Building Physics 工程技术-结构与建筑技术
CiteScore
5.10
自引率
15.00%
发文量
10
审稿时长
5.3 months
期刊介绍: Journal of Building Physics (J. Bldg. Phys) is an international, peer-reviewed journal that publishes a high quality research and state of the art “integrated” papers to promote scientifically thorough advancement of all the areas of non-structural performance of a building and particularly in heat, air, moisture transfer.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信