An electrochemical sensor based on AuPd@FexOy nanozymes for a sensitive and in situ quantitative detection of hydrogen peroxide in real samples.

Mengjiao Dai, Qunyan Zhu, Dongxue Han, L. Niu, Zhenxin Wang
{"title":"An electrochemical sensor based on AuPd@FexOy nanozymes for a sensitive and in situ quantitative detection of hydrogen peroxide in real samples.","authors":"Mengjiao Dai, Qunyan Zhu, Dongxue Han, L. Niu, Zhenxin Wang","doi":"10.2139/ssrn.4165889","DOIUrl":null,"url":null,"abstract":"The hydrogen peroxide (H2O2) levels in living organisms and environment have strong effects on many biological processes inducing cell apoptosis/cell necrosis and wound disinfection. Therefore, it is important to have an accurate and in situ detection of H2O2. Herein, an AuPd@FexOy nanozyme-based electrochemical (EC) sensor (termed as AuPd@FexOy NPs/GCE) with good stability and anti-interference ability has been prepared for the detection of H2O2 by differential pulse voltammetry (DPV) and chronoamperometry dual-measurement modes. The AuPd@FexOy NPs/GCE exhibits good linear relationships in the ranges from 13.0 to 6.0 × 103 μM (DPV measurement) and 50 to 1.0 × 103 μM (chronoamperometry measurement), low detection limits (LODs) of 1.6 μM (DPV measurement) and 3.0 μM (chronoamperometry measurement) and high sensitivities of 83.8 nA μM-1 cm-2 (DPV measurement) and 120.7 nA μM-1 cm-2 (chronoamperometry measurement). The practicability of the as-prepared AuPd@FexOy NPs/GCE has been demonstrated by an in situ real-time detection of H2O2 released from adherent living MCF-7 cells triggered by varying amounts of N-formyl-L-methionyl-L-leucyl-L-phenylalanine (FMLP) from 0.5 to 3.0 μM and the quantitative determination of H2O2 in commercial disinfectants.","PeriodicalId":82956,"journal":{"name":"The Behavior analyst","volume":"2002 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Behavior analyst","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2139/ssrn.4165889","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The hydrogen peroxide (H2O2) levels in living organisms and environment have strong effects on many biological processes inducing cell apoptosis/cell necrosis and wound disinfection. Therefore, it is important to have an accurate and in situ detection of H2O2. Herein, an AuPd@FexOy nanozyme-based electrochemical (EC) sensor (termed as AuPd@FexOy NPs/GCE) with good stability and anti-interference ability has been prepared for the detection of H2O2 by differential pulse voltammetry (DPV) and chronoamperometry dual-measurement modes. The AuPd@FexOy NPs/GCE exhibits good linear relationships in the ranges from 13.0 to 6.0 × 103 μM (DPV measurement) and 50 to 1.0 × 103 μM (chronoamperometry measurement), low detection limits (LODs) of 1.6 μM (DPV measurement) and 3.0 μM (chronoamperometry measurement) and high sensitivities of 83.8 nA μM-1 cm-2 (DPV measurement) and 120.7 nA μM-1 cm-2 (chronoamperometry measurement). The practicability of the as-prepared AuPd@FexOy NPs/GCE has been demonstrated by an in situ real-time detection of H2O2 released from adherent living MCF-7 cells triggered by varying amounts of N-formyl-L-methionyl-L-leucyl-L-phenylalanine (FMLP) from 0.5 to 3.0 μM and the quantitative determination of H2O2 in commercial disinfectants.
一种基于AuPd@FexOy纳米酶的电化学传感器,用于实际样品中过氧化氢的敏感和原位定量检测。
生物和环境中的过氧化氢(H2O2)水平对诱导细胞凋亡/细胞坏死和伤口消毒的许多生物过程有很强的影响。因此,对H2O2进行准确的原位检测非常重要。本文制备了一种稳定性好、抗干扰能力强的AuPd@FexOy纳米酶电化学(EC)传感器(AuPd@FexOy NPs/GCE),用于差分脉冲伏安法(DPV)和计时安培法双测量模式下检测H2O2。AuPd@FexOy NPs/GCE在13.0 ~ 6.0 × 103 μM (DPV测量)和50 ~ 1.0 × 103 μM(计时电流测量)范围内呈良好的线性关系,低检出限(lod)为1.6 μM (DPV测量)和3.0 μM(计时电流测量),高灵敏度为83.8 nA μM-1 cm-2 (DPV测量)和120.7 nA μM-1 cm-2(计时电流测量)。通过原位实时检测0.5 ~ 3.0 μM n -甲氧基-l -甲氧基-l -leucyl- l-苯丙氨酸(FMLP)触发MCF-7细胞释放的H2O2,以及商用消毒剂中H2O2的定量测定,证明了AuPd@FexOy NPs/GCE的实用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信