{"title":"Eradication of Enterobaracter aerogenes, Escherichia coli, Listeria monocytogene, Staphylococcus aurous, and Acetobacter by High Voltage Pulsed Electric Field in Water and Milk Samples","authors":"Md Fahim Ansari, F. Afzal, S. Mehra","doi":"10.13005/bbra/3118","DOIUrl":null,"url":null,"abstract":"ABSTRACT: Ensuring food and water safety has always been a health challenge globally. The present papers underscores HV-PEF (High Voltage Pulsed Electric Field), a novel approach to eliminate five kinds of microbes prevalent in milk and water in fractions of a second. These microorganisms are Enterobaracter aerogenes, Escherichia coli, Listeria monocytogene, Staphylococcus aurous, and Acetobacter. Objective was to find out the impact of HV-PEF on survival of selected species of bacteria, which are often considered as a concern for water and milk safety. A laboratory experimental setup was designed for producing HV-PEF, which was applied on sample of water and milk. The water sample was obtained from tap, and the milk sample was obtained from Bubalus bubalis. The microbial count was measured by plate method for both samples pre and post exposure to the HV-PEF. The effect was measured with combinations of varying field intensity and number of pulses, the intensity of the field having the highest value of 180 kV/cm (kilovolt-per-centimeter), and the pulse count varied between one to one hundred. Results showed, the endurance of few species was extremely low, at 40 kV filed intensity and 40 pulses. Other microbes also demonstrated low survival ratio (SR) at more than 40kV with pulses-count above 40. Complete inactivation of E. coli was achieved at around 80kV. The inactivation of microbe by HV-PEF varies with morphology and shape of the microorganisms. The annihilation of microorganisms is due to the rupturing of cell wall of microbe by the effect of HV-PEF, instead of ohmic heating (resistance induced).","PeriodicalId":9032,"journal":{"name":"Biosciences, Biotechnology Research Asia","volume":"30 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosciences, Biotechnology Research Asia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.13005/bbra/3118","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

ABSTRACT: Ensuring food and water safety has always been a health challenge globally. The present papers underscores HV-PEF (High Voltage Pulsed Electric Field), a novel approach to eliminate five kinds of microbes prevalent in milk and water in fractions of a second. These microorganisms are Enterobaracter aerogenes, Escherichia coli, Listeria monocytogene, Staphylococcus aurous, and Acetobacter. Objective was to find out the impact of HV-PEF on survival of selected species of bacteria, which are often considered as a concern for water and milk safety. A laboratory experimental setup was designed for producing HV-PEF, which was applied on sample of water and milk. The water sample was obtained from tap, and the milk sample was obtained from Bubalus bubalis. The microbial count was measured by plate method for both samples pre and post exposure to the HV-PEF. The effect was measured with combinations of varying field intensity and number of pulses, the intensity of the field having the highest value of 180 kV/cm (kilovolt-per-centimeter), and the pulse count varied between one to one hundred. Results showed, the endurance of few species was extremely low, at 40 kV filed intensity and 40 pulses. Other microbes also demonstrated low survival ratio (SR) at more than 40kV with pulses-count above 40. Complete inactivation of E. coli was achieved at around 80kV. The inactivation of microbe by HV-PEF varies with morphology and shape of the microorganisms. The annihilation of microorganisms is due to the rupturing of cell wall of microbe by the effect of HV-PEF, instead of ohmic heating (resistance induced).
高压脉冲电场对水和牛奶样品中产气肠杆菌、大肠杆菌、单核细胞增生李斯特菌、金黄色葡萄球菌和醋酸杆菌的去除
摘要:确保食品和水的安全一直是全球性的健康挑战。这篇论文强调了高压脉冲电场(HV-PEF),这是一种新的方法,可以在不到一秒的时间内消除牛奶和水中普遍存在的五种微生物。这些微生物是产气肠杆菌、大肠杆菌、单核细胞增生李斯特菌、金黄色葡萄球菌和醋酸杆菌。目的是了解HV-PEF对某些细菌存活的影响,这些细菌通常被认为是水和牛奶安全的问题。设计了一套用于生产HV-PEF的实验室实验装置,并将其应用于水和牛奶样品。水样取自自来水,奶样取自小绵猴。用平板法对暴露于HV-PEF前后的样品进行微生物计数测定。该效应是通过不同场强和脉冲数的组合来测量的,场强的最大值为180千伏/厘米(千伏特/厘米),脉冲数在1到100之间变化。结果表明,在40 kV场强和40次脉冲下,少数品种的耐久度极低。其他微生物在40kV以上脉冲数大于40时也表现出较低的存活率。大肠杆菌在80kV左右完全失活。HV-PEF对微生物的灭活作用因微生物的形态和形状而异。微生物的湮灭不是由于欧姆加热(电阻诱导)引起的,而是由于高压- pef作用使微生物细胞壁破裂。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信