Small, soft, and safe microactuator for retinal pigment epithelium transplantation

Yusaku Watanabe, Masanori Maeda, N. Yaji, R. Nakamura, H. Iseki, M. Yamato, T. Okano, Sadao Hori, Satoshi Konishi
{"title":"Small, soft, and safe microactuator for retinal pigment epithelium transplantation","authors":"Yusaku Watanabe, Masanori Maeda, N. Yaji, R. Nakamura, H. Iseki, M. Yamato, T. Okano, Sadao Hori, Satoshi Konishi","doi":"10.1109/MEMSYS.2007.4433083","DOIUrl":null,"url":null,"abstract":"This paper proposes a novel surgical tool for the retinal pigment epithelium (RPE) sheet transplantation. The proposed tool employs the principle of pneumatic balloon actuator (PBA). It is possible to design small, soft and safe surgical tool by using PBA because PBA is made of PDMS and driven by pneumatic pressure. These distinctive characteristics of PBA are attractive for such a challenging surgery as the RPE sheet transplantation in an eyeball. The designed head size of tool is 3 mm times 3 mm times 100 mum by taking account of the size of the RPE sheet (3 mm times 3 mm). The developed tool can perform sequential motions through independent control of different PBA so as to introduce and transplant the RPE sheet to an eyeball. Generated force by the movement of the transplantation tool is measured around 3 mN, which is allowable in an eyeball. Experimental results of both in vitro and in vivo test by using the developed tool will be reported to demonstrate feasibility of our strategy.","PeriodicalId":6388,"journal":{"name":"2007 IEEE 20th International Conference on Micro Electro Mechanical Systems (MEMS)","volume":"100 1","pages":"659-662"},"PeriodicalIF":0.0000,"publicationDate":"2007-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"48","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE 20th International Conference on Micro Electro Mechanical Systems (MEMS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MEMSYS.2007.4433083","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 48

Abstract

This paper proposes a novel surgical tool for the retinal pigment epithelium (RPE) sheet transplantation. The proposed tool employs the principle of pneumatic balloon actuator (PBA). It is possible to design small, soft and safe surgical tool by using PBA because PBA is made of PDMS and driven by pneumatic pressure. These distinctive characteristics of PBA are attractive for such a challenging surgery as the RPE sheet transplantation in an eyeball. The designed head size of tool is 3 mm times 3 mm times 100 mum by taking account of the size of the RPE sheet (3 mm times 3 mm). The developed tool can perform sequential motions through independent control of different PBA so as to introduce and transplant the RPE sheet to an eyeball. Generated force by the movement of the transplantation tool is measured around 3 mN, which is allowable in an eyeball. Experimental results of both in vitro and in vivo test by using the developed tool will be reported to demonstrate feasibility of our strategy.
小、软、安全的视网膜色素上皮移植微致动器
本文提出一种新的视网膜色素上皮(RPE)片移植手术工具。该工具采用气动球囊执行器(PBA)的工作原理。由于PBA由PDMS制成,由气压驱动,因此PBA可以设计出小巧、柔软、安全的手术工具。PBA的这些独特特征对于眼球内RPE片移植这样具有挑战性的手术是有吸引力的。考虑到RPE板材的尺寸(3mm × 3mm),设计的刀具头尺寸为3mm × 3mm × 100 mm。所开发的工具可以通过独立控制不同的PBA进行顺序运动,从而将RPE片引入眼球并移植到眼球上。移植工具运动产生的力约为3mn,这在眼球中是允许的。将报告使用开发的工具进行体外和体内测试的实验结果,以证明我们的策略的可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信