How accurate are your arc flash hazard study results

P. Barkhordar
{"title":"How accurate are your arc flash hazard study results","authors":"P. Barkhordar","doi":"10.1109/PCIC.2010.5666858","DOIUrl":null,"url":null,"abstract":"The arc flash hazard study is normally implemented based on collection and application of considerable amount of data. The significance of each piece of data on the study results are not the same, so the possible errors in collection and application of such data would not have the same impact on the final calculated incident energy. Therefore the determination of erroneous areas and how they would affect the study results will give the study engineer a better recognition of the study results reliability and how to be concerned about the validity of input data. The existing arc flash incident energy exposure calculation methodologies presented in IEEE 1584–2002/2004 and NFPA 70E-2009 standards are based on a general approach requiring three major parameters. These well-known parameters are bolted or arcing fault current, arcing time duration, and minimum working distance from the arc location. The first two, bolted or arcing fault current and arc duration, are systematic parameters calculated from configuration and characteristics of the modeled electrical network. But the minimum working distance is a physical parameter that is defined based on the voltage, enclosure, and type of the implemented task on equipment. In this paper, the possible errors in these areas and their impacts on calculation of thermal exposure to incident energy are discussed and recommendations are made to increase the possibility of achieving more conservative results leading to safer working environment.","PeriodicalId":67291,"journal":{"name":"中国石油和化工(企业版)","volume":"41 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2010-12-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国石油和化工(企业版)","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.1109/PCIC.2010.5666858","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

The arc flash hazard study is normally implemented based on collection and application of considerable amount of data. The significance of each piece of data on the study results are not the same, so the possible errors in collection and application of such data would not have the same impact on the final calculated incident energy. Therefore the determination of erroneous areas and how they would affect the study results will give the study engineer a better recognition of the study results reliability and how to be concerned about the validity of input data. The existing arc flash incident energy exposure calculation methodologies presented in IEEE 1584–2002/2004 and NFPA 70E-2009 standards are based on a general approach requiring three major parameters. These well-known parameters are bolted or arcing fault current, arcing time duration, and minimum working distance from the arc location. The first two, bolted or arcing fault current and arc duration, are systematic parameters calculated from configuration and characteristics of the modeled electrical network. But the minimum working distance is a physical parameter that is defined based on the voltage, enclosure, and type of the implemented task on equipment. In this paper, the possible errors in these areas and their impacts on calculation of thermal exposure to incident energy are discussed and recommendations are made to increase the possibility of achieving more conservative results leading to safer working environment.
你的电弧闪光危害研究结果有多准确
弧闪危害研究通常是在收集和应用大量数据的基础上进行的。由于每条数据对研究结果的意义并不相同,因此这些数据在收集和应用中可能出现的误差对最终计算的入射能的影响是不一样的。因此,错误区域的确定及其对研究结果的影响将使研究工程师更好地认识研究结果的可靠性以及如何关注输入数据的有效性。现有的电弧闪光入射能量曝光计算方法在IEEE 1584-2002/2004和NFPA 70E-2009标准中都是基于一种需要三个主要参数的通用方法。这些众所周知的参数是螺栓或电弧故障电流、电弧持续时间和距离电弧位置的最小工作距离。前两个参数,螺栓或电弧故障电流和电弧持续时间,是根据模型电网的结构和特性计算出来的系统参数。但是,最小工作距离是一个物理参数,它是根据设备上执行的任务的电压、外壳和类型来定义的。本文讨论了这些区域可能存在的误差及其对入射热暴露能量计算的影响,并提出了建议,以增加获得更保守结果的可能性,从而实现更安全的工作环境。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
346
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书