Radioterapi Linac Energi 6 MV Terhadap Kanker Serviks Pada Organ Rektum Menggunakan Teknik 3DCRT dan IMRT Di RSUP Sanglah Denpasar

Yohana Dian Savitri, G. N. Sutapa, I. W. Balik Sudarsana, Rozi Irhas
{"title":"Radioterapi Linac Energi 6 MV Terhadap Kanker Serviks Pada Organ Rektum Menggunakan Teknik 3DCRT dan IMRT Di RSUP Sanglah Denpasar","authors":"Yohana Dian Savitri, G. N. Sutapa, I. W. Balik Sudarsana, Rozi Irhas","doi":"10.29408/kpj.v6i1.4947","DOIUrl":null,"url":null,"abstract":"Cervical cancer radiotherapy on the Linac aircraft uses a 6 MV energy photon beam with 3 Dimension Conformal Radiotherapy (3DCRT) and Intensity Modulation Radiation Therapy (IMRT) techniques. Radiotherapy planning on the 3DCRT and IMRT techniques is then compared by analyzing the dose distribution or planning target volume (PTV) coverage through the Conformity Index (CI) and Homogeneity Index (HI) and Organ At Risk (OAR) where the risk organ that is considered is the rectum. In this study, 30 data on cervical cancer patients were used at the Radiotherapy Installation at Sanglah Hospital Denpasar with a plan using a box system on the 3DCRT technique and the IMRT technique with rotation angles of 00, 900, 1800, and 2700 and a radiation dose of 5000 cGy. Comparison of these two techniques is done by analyzing the Dose Volume Histogram (DVH) curve on PTV coverage on the Treatment Planning System (TPS) computer. The results of this study indicate that the average CI value in the 3DCRT technique is 1.017542 while the IMRT technique is 1.019668, with the Mann Whitney test (Asymp.Sig = 0.492). Likewise, the HI value, where the 3DCRT technique averaged 0.089494 while the IMRT technique was 0.093126 with Mann Whitney test (Asymp.Sig = 0.487), both CI and HI values were not significant. While the percentage of the average dose of the rectum on both the 3DCRT and IMRT irradiation techniques are 96% and 87%, respectively. Cervical cancer radiotherapy using IMRT technique can minimize the absorbed dose in OAR (rectum).","PeriodicalId":82301,"journal":{"name":"Phi Kappa Phi journal","volume":"26 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Phi Kappa Phi journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29408/kpj.v6i1.4947","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Cervical cancer radiotherapy on the Linac aircraft uses a 6 MV energy photon beam with 3 Dimension Conformal Radiotherapy (3DCRT) and Intensity Modulation Radiation Therapy (IMRT) techniques. Radiotherapy planning on the 3DCRT and IMRT techniques is then compared by analyzing the dose distribution or planning target volume (PTV) coverage through the Conformity Index (CI) and Homogeneity Index (HI) and Organ At Risk (OAR) where the risk organ that is considered is the rectum. In this study, 30 data on cervical cancer patients were used at the Radiotherapy Installation at Sanglah Hospital Denpasar with a plan using a box system on the 3DCRT technique and the IMRT technique with rotation angles of 00, 900, 1800, and 2700 and a radiation dose of 5000 cGy. Comparison of these two techniques is done by analyzing the Dose Volume Histogram (DVH) curve on PTV coverage on the Treatment Planning System (TPS) computer. The results of this study indicate that the average CI value in the 3DCRT technique is 1.017542 while the IMRT technique is 1.019668, with the Mann Whitney test (Asymp.Sig = 0.492). Likewise, the HI value, where the 3DCRT technique averaged 0.089494 while the IMRT technique was 0.093126 with Mann Whitney test (Asymp.Sig = 0.487), both CI and HI values were not significant. While the percentage of the average dose of the rectum on both the 3DCRT and IMRT irradiation techniques are 96% and 87%, respectively. Cervical cancer radiotherapy using IMRT technique can minimize the absorbed dose in OAR (rectum).
放射疗法Linac能源6个MV用于直肠癌症宫颈癌,使用3DCRT技术和IMRT技术在RSUP sanda Denpasar
Linac飞机上的宫颈癌放疗使用6毫伏能量光子束,结合三维适形放疗(3DCRT)和强度调制放射治疗(IMRT)技术。然后通过一致性指数(CI)、均匀性指数(HI)和危险器官(OAR)分析剂量分布或计划靶体积(PTV)覆盖率来比较3DCRT和IMRT技术的放疗计划,其中考虑的危险器官是直肠。本研究在登巴萨Sanglah医院放射治疗装置使用30例宫颈癌患者的资料,计划在3DCRT技术和IMRT技术上使用盒子系统,旋转角度为00、900、1800和2700,辐射剂量为5000 cGy。通过分析治疗计划系统(TPS)计算机上PTV覆盖的剂量体积直方图(DVH)曲线,对这两种技术进行比较。本研究结果显示,3DCRT技术的平均CI值为1.017542,IMRT技术的平均CI值为1.019668,Mann Whitney检验(asympp . sig = 0.492)。同样,HI值,其中3DCRT技术平均为0.089494,IMRT技术为0.093126,Mann Whitney检验(asympp . sig = 0.487), CI和HI值均无统计学意义。而在3DCRT和IMRT照射技术下,直肠平均剂量的百分比分别为96%和87%。应用IMRT技术进行宫颈癌放疗可使直肠吸收剂量最小化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信