Optimal Voltage Recovery Control Scheme of Wind Farm Based on Topology Reconfiguration

IF 0.2 Q4 AREA STUDIES
Shuaifeng Wang, Hanzhi Peng, Juan Wei, Guohang Huang, Sheng Huang, Lai Wei
{"title":"Optimal Voltage Recovery Control Scheme of Wind Farm Based on Topology Reconfiguration","authors":"Shuaifeng Wang, Hanzhi Peng, Juan Wei, Guohang Huang, Sheng Huang, Lai Wei","doi":"10.1109/ITECAsia-Pacific56316.2022.9942187","DOIUrl":null,"url":null,"abstract":"The collector line in wind farms (WFs) voltage sags may result in tripping the WT and consequently threaten the stability and security of wind farms (WFs). In this paper, the control scheme of WFs based on topology reconfiguration is proposed to recover the voltage of faulty WTs terminals and ensure the safe operation of the large-scale WFs. During the closed-loop process of collector lines, the impedance matrices of all closed-loop schemes are pre-calculated to get an approximation of the inrush current. The closed-loop positions of collector lines are optimized based on the integer second-order cone programming by considering the contact line cost and average voltage deviation. Finally, the fault is isolated by circuit breakers to recover the flow direction of WFs. The effectiveness of the proposed closed-loop scheme is validated in Matlab.","PeriodicalId":45126,"journal":{"name":"Asia-Pacific Journal-Japan Focus","volume":"14 1","pages":"1-7"},"PeriodicalIF":0.2000,"publicationDate":"2022-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asia-Pacific Journal-Japan Focus","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ITECAsia-Pacific56316.2022.9942187","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"AREA STUDIES","Score":null,"Total":0}
引用次数: 0

Abstract

The collector line in wind farms (WFs) voltage sags may result in tripping the WT and consequently threaten the stability and security of wind farms (WFs). In this paper, the control scheme of WFs based on topology reconfiguration is proposed to recover the voltage of faulty WTs terminals and ensure the safe operation of the large-scale WFs. During the closed-loop process of collector lines, the impedance matrices of all closed-loop schemes are pre-calculated to get an approximation of the inrush current. The closed-loop positions of collector lines are optimized based on the integer second-order cone programming by considering the contact line cost and average voltage deviation. Finally, the fault is isolated by circuit breakers to recover the flow direction of WFs. The effectiveness of the proposed closed-loop scheme is validated in Matlab.
基于拓扑重构的风电场电压恢复优化控制方案
风电场集热器线路电压骤降可能导致风电场跳闸,从而威胁到风电场的稳定和安全。本文提出了一种基于拓扑重构的wf控制方案,以恢复故障wt端子的电压,保证大型wf的安全运行。在集电极线闭环过程中,预先计算了各种闭环方案的阻抗矩阵,得到了浪涌电流的近似值。在考虑接触线成本和平均电压偏差的情况下,基于整数二阶锥规划优化集电极线闭环位置。最后通过断路器隔离故障,恢复WFs的流向。在Matlab中验证了所提闭环方案的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.20
自引率
0.00%
发文量
8
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信