{"title":"CAPILLARY ELECTROPHORESIS METHOD FOR THE DETERMINATION OF LACTULOSE AND MANNITOL RATIO FOR ESTIMATING INTESTINAL PERMEABILITY","authors":"E. Acar, D. Ö. Ünal, M. Acar, M. Koc","doi":"10.16883/JFPIU.58224","DOIUrl":null,"url":null,"abstract":"SUMMARY In this study, a simple, rapid and accurate capillary electrophoresis method has been developed for the determination of lactulose and mannitol in urine for estimating the intestinal permeability. The urine samples were prepared to analyze by using solid phase extraction. For analysis a background electrolyte (BGE) consisted of 6 mmol/L sorbic acid, 1.25mmol/L hexadecyltrimethylammoniumbromide (HDTMA), 50 mmol/L LiOH (pH 12.5) was used. Separation was performed at -5 kV over 20 min within the fused capillary column (45 cm, 50 I¼m I.D.) at 20 °C. The method developed was applied a series of urine sample to measure the lactulose/mannitol concentration rate. Key words: Lactulose, Mannitol, Determination, Permeability, Capillary electrophoresis OZET Bu calismada intestinal gecirgenligin incelenmesi amaciyla idrarda laktuloz ve mannitol tayini icin basit, hizli ve dogru bir kapiler elektroforez yontemi gelistirilmistir. Idrar ornekleri kati faz ozutleme yontemi ile analize hazirlanmistir. Analizler icin 6 mmol/L sorbik asit, 1.25 mmol/L hekzadesil trimetil amonyum bromur (HDTMA), 50 mmol/ L LiOH iceren pH si 12.5 e karsilik gelen destek elektrolit kullanilmistir. Ayrim 45 cm 50 I¼m ic capli fused silika kolonda 20 °C sicaklikta -5 kV ayirma potansiyeli kullanilarak 20 dk icerisinde gerceklestirilmistir. Gelistirilen yontem laktuloz / mannitol derisim oranlarini olcmek icin bir seri idrar numunesine uygulanmistir. Anahtar Kelimeler: Laktuloz, Mannitol, Tayin, Gecirgenlik, Kapiler elektroforez","PeriodicalId":15850,"journal":{"name":"Journal of Faculty Pharmacy of Istanbul University","volume":"343 1","pages":"13-22"},"PeriodicalIF":0.0000,"publicationDate":"2012-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Faculty Pharmacy of Istanbul University","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.16883/JFPIU.58224","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

SUMMARY In this study, a simple, rapid and accurate capillary electrophoresis method has been developed for the determination of lactulose and mannitol in urine for estimating the intestinal permeability. The urine samples were prepared to analyze by using solid phase extraction. For analysis a background electrolyte (BGE) consisted of 6 mmol/L sorbic acid, 1.25mmol/L hexadecyltrimethylammoniumbromide (HDTMA), 50 mmol/L LiOH (pH 12.5) was used. Separation was performed at -5 kV over 20 min within the fused capillary column (45 cm, 50 I¼m I.D.) at 20 °C. The method developed was applied a series of urine sample to measure the lactulose/mannitol concentration rate. Key words: Lactulose, Mannitol, Determination, Permeability, Capillary electrophoresis OZET Bu calismada intestinal gecirgenligin incelenmesi amaciyla idrarda laktuloz ve mannitol tayini icin basit, hizli ve dogru bir kapiler elektroforez yontemi gelistirilmistir. Idrar ornekleri kati faz ozutleme yontemi ile analize hazirlanmistir. Analizler icin 6 mmol/L sorbik asit, 1.25 mmol/L hekzadesil trimetil amonyum bromur (HDTMA), 50 mmol/ L LiOH iceren pH si 12.5 e karsilik gelen destek elektrolit kullanilmistir. Ayrim 45 cm 50 I¼m ic capli fused silika kolonda 20 °C sicaklikta -5 kV ayirma potansiyeli kullanilarak 20 dk icerisinde gerceklestirilmistir. Gelistirilen yontem laktuloz / mannitol derisim oranlarini olcmek icin bir seri idrar numunesine uygulanmistir. Anahtar Kelimeler: Laktuloz, Mannitol, Tayin, Gecirgenlik, Kapiler elektroforez
毛细管电泳法测定乳果糖与甘露醇比值估算肠通透性
本研究建立了一种简便、快速、准确的毛细管电泳测定尿中乳果糖和甘露醇的方法,用于估计肠道通透性。制备尿样,采用固相萃取法进行分析。背景电解液(BGE)为6 mmol/L山梨酸、1.25mmol/L十六烷基三甲基溴化铵(HDTMA)、50 mmol/L LiOH (pH 12.5)。在熔融毛细管柱(45 cm, 50 μ m id)中,在-5 kV, 20分钟内,在20°C下进行分离。将该方法应用于一系列尿样中乳果糖/甘露醇浓度率的测定。【关键词】乳果糖,甘露醇,测定,渗透性,毛细管电泳OZET;甘露醇,甘露醇;甘露醇;Idrar或nekleri kati faz ozutleme将分析hazirlanmiir。分析剂为6 mmol/L山梨酸,1.25 mmol/L三甲基溴铵(HDTMA), 50 mmol/L LiOH, pH值为12.5 mmol/L karsilik gelen destek eletrolit kullanilmisir。直径45厘米,直径50厘米,直径1 / 4厘米,直径20°C,直径5千伏,直径5千伏,直径5千伏,直径20千伏,直径5千伏。Gelistirilen system - laktuloz / mannitol - derisim - oranlarini - olmek是一种新型的化学物质。Anahtar Kelimeler: Laktuloz, Mannitol, Tayin, gerecgenlik, Kapiler elektroforez
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信