Forced Degradation Study of Monoclonal Antibody Using Two-Dimensional Liquid Chromatography

Y. An, S. Verma, Y. Chen, S. Yu, Y. Zhang, S. Kelner, S. Mengisen, D. Richardson, Z. Chen
{"title":"Forced Degradation Study of Monoclonal Antibody Using Two-Dimensional Liquid Chromatography","authors":"Y. An, S. Verma, Y. Chen, S. Yu, Y. Zhang, S. Kelner, S. Mengisen, D. Richardson, Z. Chen","doi":"10.4172/2157-7064.1000365","DOIUrl":null,"url":null,"abstract":"Monoclonal antibody (mAb) products are extraordinarily heterogeneous due to the presence of a variety of enzymatic and chemical modifications, such as deamidation, isomerization, oxidation, glycosylation, glycation, terminal cyclization, aggregation, and fragmentation. Forced degradation study is a common practice to assess the potential modifications and degradation pathways of mAbs upon extreme conditions, including light exposure and extreme local pH. The degraded samples are subject to characterization using a wide array of analyses, including ion exchange chromatography (IEC) for charge variants and size exclusion chromatography (SEC) for size variants. In this proof-of-concept study, a two-dimensional liquid chromatography (2D-LC) approach was successfully applied to mAb forced degradation samples for evaluation of size distribution in the IEC charge profile. The charge variant peaks in first-dimension (1D) IEC were fractioned by a heart-cutting schedule, and the integrated peak parking feature accommodated later-eluting 1D cuts when the previous ones were still under second-dimension (2D) analysis. Thus, for a singly IEC injection, all IEC fractions were acquired by the 2D for SEC analysis. This study demonstrated that 2D SEC was compatible with 1D IEC for 2D-LC analysis. The method sensitivity was sufficient to determine the aggregates and fragments in each individual IEC cut. The calculated total aggregates and fragments in the stressed mAb-1 samples were comparable to those detected by one dimensional SEC. Most importantly, the 2D IEC-SEC approach was capable of bridging the mAb charge and size variants in a real-time and efficient manner. It was observed that aggregates were enriched in the most basic region in the IEC charge profile, especially in the highly degraded samples. This is the first IEC-SEC 2D-LC application for intact antibody analysis as per the authors’ knowledge.","PeriodicalId":15534,"journal":{"name":"Journal of Chromatography & Separation Techniques","volume":"105 1","pages":"1-7"},"PeriodicalIF":0.0000,"publicationDate":"2017-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chromatography & Separation Techniques","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4172/2157-7064.1000365","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

Abstract

Monoclonal antibody (mAb) products are extraordinarily heterogeneous due to the presence of a variety of enzymatic and chemical modifications, such as deamidation, isomerization, oxidation, glycosylation, glycation, terminal cyclization, aggregation, and fragmentation. Forced degradation study is a common practice to assess the potential modifications and degradation pathways of mAbs upon extreme conditions, including light exposure and extreme local pH. The degraded samples are subject to characterization using a wide array of analyses, including ion exchange chromatography (IEC) for charge variants and size exclusion chromatography (SEC) for size variants. In this proof-of-concept study, a two-dimensional liquid chromatography (2D-LC) approach was successfully applied to mAb forced degradation samples for evaluation of size distribution in the IEC charge profile. The charge variant peaks in first-dimension (1D) IEC were fractioned by a heart-cutting schedule, and the integrated peak parking feature accommodated later-eluting 1D cuts when the previous ones were still under second-dimension (2D) analysis. Thus, for a singly IEC injection, all IEC fractions were acquired by the 2D for SEC analysis. This study demonstrated that 2D SEC was compatible with 1D IEC for 2D-LC analysis. The method sensitivity was sufficient to determine the aggregates and fragments in each individual IEC cut. The calculated total aggregates and fragments in the stressed mAb-1 samples were comparable to those detected by one dimensional SEC. Most importantly, the 2D IEC-SEC approach was capable of bridging the mAb charge and size variants in a real-time and efficient manner. It was observed that aggregates were enriched in the most basic region in the IEC charge profile, especially in the highly degraded samples. This is the first IEC-SEC 2D-LC application for intact antibody analysis as per the authors’ knowledge.
单克隆抗体的二维液相色谱强制降解研究
由于多种酶和化学修饰的存在,单克隆抗体(mAb)产物是非常不均匀的,如脱酰胺、异构化、氧化、糖基化、糖基化、末端环化、聚集和片段化。强制降解研究是评估单克隆抗体在极端条件下的潜在修饰和降解途径的一种常见做法,包括光暴露和极端的局部ph。降解的样品需要使用广泛的分析来进行表征,包括离子交换色谱(IEC)用于电荷变化和尺寸排除色谱(SEC)用于尺寸变化。在这项概念验证研究中,二维液相色谱(2D-LC)方法成功地应用于单抗强制降解样品,以评估IEC电荷剖面中的尺寸分布。在一维(1D) IEC中,电荷变化峰通过心形切割计划进行分划,当之前的电荷变化峰仍在二维(2D)分析中时,集成的峰值停放特征可容纳后洗脱的1D切割。因此,对于单次IEC注入,所有的IEC分数都是由2D获得的,用于SEC分析。本研究表明,2D SEC与1D IEC兼容,可用于2D- lc分析。该方法的灵敏度足以确定每个单独的IEC切割中的聚集体和碎片。应力单抗-1样品中计算的总聚集体和片段与一维SEC检测的结果相当。最重要的是,二维IEC-SEC方法能够实时有效地桥接单抗电荷和大小变化。我们观察到聚集物在IEC电荷剖面中最基本的区域富集,特别是在高度降解的样品中。据作者所知,这是第一个用于完整抗体分析的IEC-SEC 2D-LC应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书