{"title":"Daily improvement of blood glucose profile by continuous glucose monitoring (CGM)","authors":"H. Bando, Y. Kato, S. Kanazawa, Mayumi Tanaka, E. Sueki, H. Kanagawa, T. Kawata, A. Kawahito, A. Aihara","doi":"10.15406/JDMDC.2019.06.00177","DOIUrl":null,"url":null,"abstract":"Background: The problem of glucose variability has been in focus for type 1 diabetes mellitus (T1DM) on insulin treatment. Daily profile of blood glucose was studied on Continuous Glucose Monitoring (CGM) using Free Style Libre. Case presentation and results: Patient is 54 year-old T1DM female, with HbA1c 7.8%. The blood glucose variability was measured by Free Style Libre. Insulin therapy included multiple daily insulin injection (MDI) of Insulin Glargin and Aspart. The result revealed unstable blood glucose profile in day 1 and 2. After that, the level and fluctuation of blood glucose gradually decreased from day 3 to 14. Average blood glucose in a day was 174mg/dL, 159mg/dL, 138mg/dL, 125mg/dL and 110mg/dL, in day 2, 4, 7, 9, 11, respectively. There was a discrepancy of HbA1c between 7.8% by laboratory measurement and 6.3% presumed value by Free Style Libre. Discussion and Conclusion: Free Style Libre showed satisfactory results as CGM. There was lower HbA1c value by presumed calculation, which would be possibly due to every 15minutes measurement and difficulty in checking abrupt glucose surges. CGM application would probably bring diabetic subjects behavioral change of life style, leading to better diabetic control. These results would become reference data in CGM study for future research.","PeriodicalId":92240,"journal":{"name":"Journal of diabetes, metabolic disorders & control","volume":"26 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of diabetes, metabolic disorders & control","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15406/JDMDC.2019.06.00177","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Background: The problem of glucose variability has been in focus for type 1 diabetes mellitus (T1DM) on insulin treatment. Daily profile of blood glucose was studied on Continuous Glucose Monitoring (CGM) using Free Style Libre. Case presentation and results: Patient is 54 year-old T1DM female, with HbA1c 7.8%. The blood glucose variability was measured by Free Style Libre. Insulin therapy included multiple daily insulin injection (MDI) of Insulin Glargin and Aspart. The result revealed unstable blood glucose profile in day 1 and 2. After that, the level and fluctuation of blood glucose gradually decreased from day 3 to 14. Average blood glucose in a day was 174mg/dL, 159mg/dL, 138mg/dL, 125mg/dL and 110mg/dL, in day 2, 4, 7, 9, 11, respectively. There was a discrepancy of HbA1c between 7.8% by laboratory measurement and 6.3% presumed value by Free Style Libre. Discussion and Conclusion: Free Style Libre showed satisfactory results as CGM. There was lower HbA1c value by presumed calculation, which would be possibly due to every 15minutes measurement and difficulty in checking abrupt glucose surges. CGM application would probably bring diabetic subjects behavioral change of life style, leading to better diabetic control. These results would become reference data in CGM study for future research.
通过连续血糖监测(CGM)改善每日血糖状况
背景:胰岛素治疗对1型糖尿病(T1DM)的血糖变异性问题一直是关注的焦点。采用Free Style Libre连续血糖监测仪(CGM)研究每日血糖变化。病例介绍和结果:患者54岁,T1DM女性,HbA1c 7.8%。采用Free Style Libre测量血糖变异性。胰岛素治疗包括每日多次胰岛素注射(MDI)甘精胰岛素和阿斯帕特。结果显示第1天和第2天血糖不稳定。之后,从第3天到第14天,血糖水平和波动逐渐降低。第2天、第4天、第7天、第9天、第11天的日均血糖分别为174mg/dL、159mg/dL、138mg/dL、125mg/dL和110mg/dL。HbA1c在实验室测量值7.8%与Free Style Libre推测值6.3%之间存在差异。讨论与结论:自由式自由泳作为CGM具有满意的效果。假定计算HbA1c值较低,这可能是由于每15分钟测量一次,难以检查突然的血糖激增。CGM的应用可能会带来糖尿病患者生活方式的行为改变,从而更好地控制糖尿病。这些结果为今后的CGM研究提供了参考数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信