{"title":"E12 technique: Conventional epoxy resin sheet plastination","authors":"R. Latorre, K. de Jong, M. Șora, O. López-Albors, C. Baptista","doi":"10.1111/ahe.12507","DOIUrl":null,"url":null,"abstract":"Epoxy plastination techniques were developed to obtain thin transparent body slices with high anatomical detail. This is facilitated because the plastinated tissue is transparent and the topography of the anatomical structures well preserved. For this reason, thin epoxy slices are currently used for research purposes in both macroscopic and microscopic studies. The protocol for the conventional epoxy technique (E12) follows the main steps of plastination—specimen preparation, dehydration, impregnation and curing/casting. Preparation begins with selection of the specimen, followed by freezing and slicing. Either fresh or fixed (embalmed) tissue is suitable for epoxy plastination, while slice thickness is kept between 1.5 and 3 mm. Impregnation mixture is made of epoxy E12 resin plus E1 hardener (100 ppw; 28 ppw). This mixture is reactive and temperature sensitive, and for this reason, total impregnation time under vacuum at room laboratory temperature should not last for more than 20–24 hr. Casting of impregnated slices is done in either flat chambers or by the so‐called sandwich method in either fresh mixture or the one used for impregnation. Curing is completed at 40°C to allow a complete polymerization of the epoxy‐mixture. After curing, slices can be photographed, scanned or used for anatomical study under screen negatoscope, magnification glass or fluorescent microscope. Based on epoxy sheet plastination, many anatomical papers have recent observations of and/or clarification of anatomical concepts in different areas of medical expertice.","PeriodicalId":7888,"journal":{"name":"Anatomia","volume":"135 1","pages":"557 - 563"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anatomia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1111/ahe.12507","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Epoxy plastination techniques were developed to obtain thin transparent body slices with high anatomical detail. This is facilitated because the plastinated tissue is transparent and the topography of the anatomical structures well preserved. For this reason, thin epoxy slices are currently used for research purposes in both macroscopic and microscopic studies. The protocol for the conventional epoxy technique (E12) follows the main steps of plastination—specimen preparation, dehydration, impregnation and curing/casting. Preparation begins with selection of the specimen, followed by freezing and slicing. Either fresh or fixed (embalmed) tissue is suitable for epoxy plastination, while slice thickness is kept between 1.5 and 3 mm. Impregnation mixture is made of epoxy E12 resin plus E1 hardener (100 ppw; 28 ppw). This mixture is reactive and temperature sensitive, and for this reason, total impregnation time under vacuum at room laboratory temperature should not last for more than 20–24 hr. Casting of impregnated slices is done in either flat chambers or by the so‐called sandwich method in either fresh mixture or the one used for impregnation. Curing is completed at 40°C to allow a complete polymerization of the epoxy‐mixture. After curing, slices can be photographed, scanned or used for anatomical study under screen negatoscope, magnification glass or fluorescent microscope. Based on epoxy sheet plastination, many anatomical papers have recent observations of and/or clarification of anatomical concepts in different areas of medical expertice.
E12工艺:常规环氧树脂板材塑化
环氧树脂塑化技术的发展,以获得薄透明的身体切片高解剖细节。这是很容易的,因为塑化组织是透明的,解剖结构的地形保存得很好。因此,薄环氧树脂片目前用于宏观和微观研究。常规环氧树脂技术(E12)的方案遵循塑化-试样制备,脱水,浸渍和固化/铸造的主要步骤。准备工作从标本的选择开始,然后冷冻和切片。新鲜或固定(防腐)组织都适合环氧塑化,切片厚度保持在1.5 - 3mm之间。浸渍混合物为环氧E12树脂加E1硬化剂(100ppw;28 ppw)。该混合物具有反应性和温度敏感性,因此,在室温真空下的总浸渍时间不应超过20-24小时。浸渍片的铸造可以在平腔中进行,也可以用所谓的夹心法在新鲜混合物或浸渍所用的混合物中进行。固化在40°C下完成,以使环氧混合物完全聚合。固化后,切片可在屏幕负像镜、放大镜或荧光显微镜下拍照、扫描或用于解剖研究。基于环氧树脂片塑化,许多解剖论文最近观察和/或澄清解剖概念在不同的医学领域的经验。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书