Contact inspection and resistance–capacitance measurement of Si nanowire with SEM voltage contrast

IF 1.5 2区 物理与天体物理 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC
T. Ohashi, K. Hasumi, M. Ikota, G. Lorusso, H. Mertens, N. Horiguchi
{"title":"Contact inspection and resistance–capacitance measurement of Si nanowire with SEM voltage contrast","authors":"T. Ohashi, K. Hasumi, M. Ikota, G. Lorusso, H. Mertens, N. Horiguchi","doi":"10.1117/1.JMM.18.2.021205","DOIUrl":null,"url":null,"abstract":"Abstract. A methodology to evaluate the electrical contact between nanowire (NW) and source/drain in NW FETs was investigated with SEM voltage contrast (VC). The electrical defects are robustly detected by VC. The validity of the inspection result was verified by transmission electron microscope (TEM) physical observations. Moreover, estimation of the parasitic resistance and capacitance was achieved from the quantitative analysis of VC images, which are acquired with different scan conditions of an electron beam (EB). A model considering the dynamics of EB-induced charging was proposed to calculate the VC. The resistance and capacitance can be determined by comparing the model-based VC with experimentally obtained VC. Quantitative estimation of resistance and capacitance would be valuable not only for more accurate inspection but also for identification of the defect point.","PeriodicalId":16522,"journal":{"name":"Journal of Micro/Nanolithography, MEMS, and MOEMS","volume":"13 1","pages":"021205 - 021205"},"PeriodicalIF":1.5000,"publicationDate":"2019-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Micro/Nanolithography, MEMS, and MOEMS","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1117/1.JMM.18.2.021205","RegionNum":2,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 2

Abstract

Abstract. A methodology to evaluate the electrical contact between nanowire (NW) and source/drain in NW FETs was investigated with SEM voltage contrast (VC). The electrical defects are robustly detected by VC. The validity of the inspection result was verified by transmission electron microscope (TEM) physical observations. Moreover, estimation of the parasitic resistance and capacitance was achieved from the quantitative analysis of VC images, which are acquired with different scan conditions of an electron beam (EB). A model considering the dynamics of EB-induced charging was proposed to calculate the VC. The resistance and capacitance can be determined by comparing the model-based VC with experimentally obtained VC. Quantitative estimation of resistance and capacitance would be valuable not only for more accurate inspection but also for identification of the defect point.
硅纳米线接触面检测及SEM电压对比电阻-电容测量
摘要采用扫描电镜电压对比(VC)技术研究了纳米线(NW)与NW场效应管源极/漏极电接触的评价方法。利用VC对电缺陷进行了鲁棒检测。通过透射电镜(TEM)物理观察验证了检测结果的有效性。此外,通过对不同电子束扫描条件下获得的VC图像进行定量分析,获得了寄生电阻和寄生电容的估计。提出了一个考虑eb诱导充电动力学的模型来计算VC。通过将基于模型的VC与实验得到的VC进行比较,可以确定电阻和电容。电阻和电容的定量估计不仅对更精确的检测有价值,而且对缺陷点的识别也有价值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.40
自引率
30.40%
发文量
0
审稿时长
6-12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信