Comparison of numerical aperture increasing lens and standard subsurface microscopy

S. Ippolito, B. Goldberg, M. Unlu
{"title":"Comparison of numerical aperture increasing lens and standard subsurface microscopy","authors":"S. Ippolito, B. Goldberg, M. Unlu","doi":"10.1109/LEOS.2001.969044","DOIUrl":null,"url":null,"abstract":"Subsurface inspection of a Si integrated circuit (IC) by a Numerical Aperture Increasing Lens (NAIL) microscope has yielded a lateral spatial resolution of better than 0.23 /spl mu/m. We compare NAIL microscopy to standard subsurface microscopy using the Hamamatsu /spl mu/AMOS-200, IC Failure Analysis System. The NAIL improves the microscope's lateral spatial resolution from /spl sim/1.7 /spl mu/m to /spl sim/0.3 /spl mu/m. It is difficult to obtain the longitudinal spatial resolution because the sample has multiple longitudinal dielectric interfaces.","PeriodicalId":18008,"journal":{"name":"LEOS 2001. 14th Annual Meeting of the IEEE Lasers and Electro-Optics Society (Cat. No.01CH37242)","volume":"52 1","pages":"774-775 vol.2"},"PeriodicalIF":0.0000,"publicationDate":"2001-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"LEOS 2001. 14th Annual Meeting of the IEEE Lasers and Electro-Optics Society (Cat. No.01CH37242)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/LEOS.2001.969044","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Subsurface inspection of a Si integrated circuit (IC) by a Numerical Aperture Increasing Lens (NAIL) microscope has yielded a lateral spatial resolution of better than 0.23 /spl mu/m. We compare NAIL microscopy to standard subsurface microscopy using the Hamamatsu /spl mu/AMOS-200, IC Failure Analysis System. The NAIL improves the microscope's lateral spatial resolution from /spl sim/1.7 /spl mu/m to /spl sim/0.3 /spl mu/m. It is difficult to obtain the longitudinal spatial resolution because the sample has multiple longitudinal dielectric interfaces.
数值孔径增大透镜与标准地下显微镜的比较
采用数值孔径增大透镜(NAIL)显微镜对硅集成电路(IC)进行亚表面检测,其横向空间分辨率优于0.23 /spl mu/m。我们使用Hamamatsu /spl mu/ amos - 200ic失效分析系统将NAIL显微镜与标准地下显微镜进行比较。NAIL将显微镜的横向空间分辨率从/spl sim/1.7 /spl mu/m提高到/spl sim/0.3 /spl mu/m。由于样品具有多个纵向介质界面,因此难以获得纵向空间分辨率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信