A low-cost, optical feedback laser range-finder with chirp-control

T. Bosch, S. Pavageau, D. D’Alessandro, N. Servagent, V. Annovazzi-Lodi, S. Donati
{"title":"A low-cost, optical feedback laser range-finder with chirp-control","authors":"T. Bosch, S. Pavageau, D. D’Alessandro, N. Servagent, V. Annovazzi-Lodi, S. Donati","doi":"10.1109/IMTC.2001.928244","DOIUrl":null,"url":null,"abstract":"A new laser range finder using optical feedback interferometry and wavelength sweep has been developed. Our aim was to design a high-accuracy sensor for operation on short distances, using a low-cost Mach-Zender interferometer to separately measure the chirp of the laser. Experimentally, on a plain diffusing target, at a 10-cm distance, we were able to demonstrate an accuracy of 100 /spl mu/m. Projected accuracy is down to 20-50 /spl mu/m.","PeriodicalId":68878,"journal":{"name":"Journal of Measurement Science and Instrumentation","volume":"59 1","pages":"1070-1074 vol.2"},"PeriodicalIF":0.0000,"publicationDate":"2001-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Measurement Science and Instrumentation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMTC.2001.928244","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

A new laser range finder using optical feedback interferometry and wavelength sweep has been developed. Our aim was to design a high-accuracy sensor for operation on short distances, using a low-cost Mach-Zender interferometer to separately measure the chirp of the laser. Experimentally, on a plain diffusing target, at a 10-cm distance, we were able to demonstrate an accuracy of 100 /spl mu/m. Projected accuracy is down to 20-50 /spl mu/m.
具有啁啾控制的低成本光学反馈激光测距仪
研制了一种采用光反馈干涉和波长扫描的新型激光测距仪。我们的目标是设计一种用于短距离操作的高精度传感器,使用低成本的Mach-Zender干涉仪单独测量激光的啁啾。实验上,在一个普通的扩散目标上,在10厘米的距离上,我们能够证明100 /spl μ m /m的精度。预测精度降至20-50 /spl mu/m。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
927
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信