{"title":"Radiofrequency Ablation Versus High-Frequency Ablation In-Vivo Comparison","authors":"A. Rouane, P. Bru, D. Kourtiche","doi":"10.5923/J.AJBE.20120203.05","DOIUrl":null,"url":null,"abstract":"The high frequency (HF) intracardiac ablation has shown its ability to obtain atrioventricular blocks (AVB) with relatively low power. In this paper, the equipment used in High Frequency (HF) ablation technique is described. The frequency used is from 500 kHz to 1 MHz in the case of Radiofrequency (RF) technique and 27.12 MHz for HF technique. Ablation under the same conditions using the Nakagawa protocol was done. Quantitative comparison of the two methods shows efficiency of the HF technique. The results obtained in this study show that the HF technique produces lesions wider and deeper than that obtained with RF technique. Thus, HF technique is more appropriate for cardiac ablations in the ventricle. The results also showed that HF technique provides linear lesions thus delimiting the necrotic tissue from healthy tissue. With the RF technical, dimensions of the obtained lesion are (9x7x5) mm 3 for 270 joules applied power. With the same energy, the dimensions of lesion are (10x9x5) mm 3 for the HF Technique.","PeriodicalId":7620,"journal":{"name":"American Journal of Biomedical Engineering","volume":"318 1","pages":"120-123"},"PeriodicalIF":0.0000,"publicationDate":"2012-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Biomedical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5923/J.AJBE.20120203.05","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The high frequency (HF) intracardiac ablation has shown its ability to obtain atrioventricular blocks (AVB) with relatively low power. In this paper, the equipment used in High Frequency (HF) ablation technique is described. The frequency used is from 500 kHz to 1 MHz in the case of Radiofrequency (RF) technique and 27.12 MHz for HF technique. Ablation under the same conditions using the Nakagawa protocol was done. Quantitative comparison of the two methods shows efficiency of the HF technique. The results obtained in this study show that the HF technique produces lesions wider and deeper than that obtained with RF technique. Thus, HF technique is more appropriate for cardiac ablations in the ventricle. The results also showed that HF technique provides linear lesions thus delimiting the necrotic tissue from healthy tissue. With the RF technical, dimensions of the obtained lesion are (9x7x5) mm 3 for 270 joules applied power. With the same energy, the dimensions of lesion are (10x9x5) mm 3 for the HF Technique.
高频(HF)心内消融术已显示出其以相对低功率获得房室传导阻滞(AVB)的能力。本文介绍了用于高频烧蚀技术的设备。射频(RF)技术使用的频率为500khz至1mhz,高频技术使用的频率为27.12 MHz。在相同条件下使用Nakagawa方案进行消融。两种方法的定量比较表明了高频技术的有效性。本研究的结果表明,高频技术比射频技术产生的病变更宽、更深。因此,高频消融技术更适用于心室内的心脏消融。结果还显示HF技术提供线性病变,从而将坏死组织与健康组织区分开来。使用射频技术,在施加270焦耳的功率下,获得的病变尺寸为(9x7x5) mm 3。在相同能量下,高频技术的病变尺寸为(10x9x5) mm 3。