Thermal management of liquid-cooled cold plates for multiple heat sources in a humanoid robot

S. Kim, Kyudae Hwang, Jong-Chul Moon, S. Karng
{"title":"Thermal management of liquid-cooled cold plates for multiple heat sources in a humanoid robot","authors":"S. Kim, Kyudae Hwang, Jong-Chul Moon, S. Karng","doi":"10.1109/IMPACT.2009.5382215","DOIUrl":null,"url":null,"abstract":"Thermal management for two array types of a serial circulation and a two-way parallel circulation using six mini liquid-cooled cold plates were experimentally measured in this study. In order to reduce weight of the cooling devices for humanoid robot cooling, the cold plates were covered with non-metallic material (polycarbonate, PC). Six cold plates attached on 10 x 10 mm2 copper base: 0.5 x 0.5 mm2 pin-finned surfaces of 1.5 mm high with 0.5 mm array spacing, was mounted on six copper heating blocks with isothermal conditions of 50~90°C, respectively. In order to compare thermal characteristics according to two circulation types, the surface temperatures of heating blocks and the cooling water temperatures at inlets and outlets of cold plates were measured. From the results, it was found that a two-way parallel circulation was better performance than a serial circulation in terms of total thermal resistance, total heat transfer rate, and surface temperature rises from first heating block to last one for six multiple cold plates.","PeriodicalId":6410,"journal":{"name":"2009 4th International Microsystems, Packaging, Assembly and Circuits Technology Conference","volume":"96 1","pages":"453-456"},"PeriodicalIF":0.0000,"publicationDate":"2009-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 4th International Microsystems, Packaging, Assembly and Circuits Technology Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMPACT.2009.5382215","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

Thermal management for two array types of a serial circulation and a two-way parallel circulation using six mini liquid-cooled cold plates were experimentally measured in this study. In order to reduce weight of the cooling devices for humanoid robot cooling, the cold plates were covered with non-metallic material (polycarbonate, PC). Six cold plates attached on 10 x 10 mm2 copper base: 0.5 x 0.5 mm2 pin-finned surfaces of 1.5 mm high with 0.5 mm array spacing, was mounted on six copper heating blocks with isothermal conditions of 50~90°C, respectively. In order to compare thermal characteristics according to two circulation types, the surface temperatures of heating blocks and the cooling water temperatures at inlets and outlets of cold plates were measured. From the results, it was found that a two-way parallel circulation was better performance than a serial circulation in terms of total thermal resistance, total heat transfer rate, and surface temperature rises from first heating block to last one for six multiple cold plates.
人形机器人多热源液冷冷板的热管理
采用6个小型液冷冷板对串联循环和双向平行循环两种阵列的热管理进行了实验研究。为了减轻人形机器人冷却装置的重量,冷板采用非金属材料(聚碳酸酯、PC)覆盖。6个冷板分别安装在10 × 10 mm2铜底座上:0.5 × 0.5 mm2针翅面,高1.5 mm,阵列间距0.5 mm,分别安装在等温条件为50~90°C的6个铜加热块上。为了比较两种循环方式的热特性,测量了加热块表面温度和冷板进出口冷却水温度。结果表明,对于6块多冷板,双向平行循环在总热阻、总换热率以及从第一个加热块到最后一个加热块的表面温升方面优于串联循环。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信