Ultrasound transducer sensitivity in non linear parameter measurement

D. Kourtiche, M. Nadi, A. Rouane, A. Chitnalah
{"title":"Ultrasound transducer sensitivity in non linear parameter measurement","authors":"D. Kourtiche, M. Nadi, A. Rouane, A. Chitnalah","doi":"10.1109/ICSENST.2008.4757128","DOIUrl":null,"url":null,"abstract":"We present a procedure for measurement of the non linear B/A parameter using a simple comparative method. A theoretical model of the measurement system is proposed. A function sensitivity of the system is derived in order to connect the electric and acoustic magnitudes. Thus the optimal conditions in order to avoid complex calculation of the transducers sensitivities were carried out. We showed that the sensitivity function of the measurement system can be kept close to the unit by making a good choice of the fundamental frequency. Indeed if the frequency of the source transducer is chosen less than the resonance frequency we can avoid determining the sensitivities. Measurements had been carried out to validate the procedure and the theoretical aspects.","PeriodicalId":6299,"journal":{"name":"2008 3rd International Conference on Sensing Technology","volume":"20 1","pages":"358-362"},"PeriodicalIF":0.0000,"publicationDate":"2008-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 3rd International Conference on Sensing Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENST.2008.4757128","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

We present a procedure for measurement of the non linear B/A parameter using a simple comparative method. A theoretical model of the measurement system is proposed. A function sensitivity of the system is derived in order to connect the electric and acoustic magnitudes. Thus the optimal conditions in order to avoid complex calculation of the transducers sensitivities were carried out. We showed that the sensitivity function of the measurement system can be kept close to the unit by making a good choice of the fundamental frequency. Indeed if the frequency of the source transducer is chosen less than the resonance frequency we can avoid determining the sensitivities. Measurements had been carried out to validate the procedure and the theoretical aspects.
超声换能器在非线性参数测量中的灵敏度
我们提出了用简单的比较法测量非线性B/ a参数的程序。提出了测量系统的理论模型。推导了系统的函数灵敏度,以便将电量值和声量值联系起来。为了避免传感器灵敏度的复杂计算,给出了最佳条件。结果表明,通过选择合适的基频,可以使测量系统的灵敏度函数与单元保持接近。事实上,如果选择源换能器的频率小于共振频率,我们可以避免确定灵敏度。已经进行了测量以验证程序和理论方面。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信