Simultaneous Determination of Ammonium Ion, MDEA, Common Metal Cations and Dialkyl Amines in Amine Processing Solution by Ion Chromatography

Ravindra Singh, M. Khan, A. Yadav, A. Chopra, Kagdiyal
{"title":"Simultaneous Determination of Ammonium Ion, MDEA, Common Metal Cations and Dialkyl Amines in Amine Processing Solution by Ion Chromatography","authors":"Ravindra Singh, M. Khan, A. Yadav, A. Chopra, Kagdiyal","doi":"10.4172/2157-7064.1000416","DOIUrl":null,"url":null,"abstract":"In the present study a new method has been developed for the separation and estimation of common metal cations (Li+, Na+, K+), Methyl diethanolamine (MDEA) (and types of alkyl amines) and their degradation products including ammonium ion used in amine processing solution. The acid treating amines such as dimethyl amine (DMA), Diethyl amine (DEA), Dipropylamine (DPA), Diisopropyl amine (DPA) and Dibutyl amine (DBA) in amine processing solution have been separated by Ion Chromatography (IC) using conductivity detector in single column mode. Desired separation was achieved within 20 min using mixture of 3 mM CH3SO3H+CH3CN (90:10) as mobile phase on Dionex Ion Pac SCS1 column at temperature of 30°C. Calibration curve for all the cations (Li+, Na+, K+, NH4+) in the concentration range of 2.5-20 ppm and 3-100 ppm for dialkyl amine were plotted and it was observed that the correlation coefficient (R2) list in between 0.9980 and 1.0. Relative Standard Deviation (RSD) observed for all the abovementioned cations were in the range of 0.81-2.33%. Recovery of all the cations at different concentrations of amine processing matrix was in the range of 80-120%. The lower Limit of Detection (LOD) for Li+, Na+, K+, NH4+ was 0.5 ppm, and for MDEA and all above alkyl amines was 1.0 ppm. The operational simplicity of this method in terms of accuracy and precision can be a good alternative for the estimation of above ions in amine processing solution.","PeriodicalId":15534,"journal":{"name":"Journal of Chromatography & Separation Techniques","volume":"222 1","pages":"1-7"},"PeriodicalIF":0.0000,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chromatography & Separation Techniques","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4172/2157-7064.1000416","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

In the present study a new method has been developed for the separation and estimation of common metal cations (Li+, Na+, K+), Methyl diethanolamine (MDEA) (and types of alkyl amines) and their degradation products including ammonium ion used in amine processing solution. The acid treating amines such as dimethyl amine (DMA), Diethyl amine (DEA), Dipropylamine (DPA), Diisopropyl amine (DPA) and Dibutyl amine (DBA) in amine processing solution have been separated by Ion Chromatography (IC) using conductivity detector in single column mode. Desired separation was achieved within 20 min using mixture of 3 mM CH3SO3H+CH3CN (90:10) as mobile phase on Dionex Ion Pac SCS1 column at temperature of 30°C. Calibration curve for all the cations (Li+, Na+, K+, NH4+) in the concentration range of 2.5-20 ppm and 3-100 ppm for dialkyl amine were plotted and it was observed that the correlation coefficient (R2) list in between 0.9980 and 1.0. Relative Standard Deviation (RSD) observed for all the abovementioned cations were in the range of 0.81-2.33%. Recovery of all the cations at different concentrations of amine processing matrix was in the range of 80-120%. The lower Limit of Detection (LOD) for Li+, Na+, K+, NH4+ was 0.5 ppm, and for MDEA and all above alkyl amines was 1.0 ppm. The operational simplicity of this method in terms of accuracy and precision can be a good alternative for the estimation of above ions in amine processing solution.
离子色谱法同时测定胺处理液中的铵离子、MDEA、常见金属阳离子和二烷基胺
本研究提出了一种分离和测定常见金属阳离子(Li+, Na+, K+)、甲基二乙醇胺(MDEA)(以及各种烷基胺)及其在胺处理溶液中的降解产物(包括铵离子)的新方法。采用离子色谱(IC)单柱电导率检测器对胺处理液中的二甲基胺(DMA)、二乙基胺(DEA)、二丙胺(DPA)、二异丙胺(DPA)和二丁基胺(DBA)等酸处理胺进行了分离。以3mm CH3SO3H+CH3CN(90:10)的混合物为流动相,在Dionex Ion Pac SCS1色谱柱上,温度为30℃,在20 min内达到预期的分离效果。绘制了二烷基胺在2.5 ~ 20 ppm和3 ~ 100 ppm浓度范围内所有阳离子(Li+、Na+、K+、NH4+)的校准曲线,相关系数(R2)表在0.9980 ~ 1.0之间。上述阳离子的相对标准偏差(RSD)在0.81 ~ 2.33%之间。在不同浓度的胺处理基质中,阳离子的回收率在80 ~ 120%之间。Li+、Na+、K+、NH4+的检出下限为0.5 ppm, MDEA及以上所有烷基胺的检出下限为1.0 ppm。该方法在准确度和精密度方面操作简便,可作为胺处理溶液中上述离子的一种很好的替代方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书