{"title":"A PEBB-based direct-link drive for open-ended AC machines","authors":"A. Somani, R. Gupta, T. Satish, K. K. Mohapatra","doi":"10.1145/1357910.1357929","DOIUrl":null,"url":null,"abstract":"A PEBB-based direct-link converter arrangement for the control of an open-ended three-phase machine is analyzed in this paper. The converter arrangement requires only 18 unidirectional switches as compared to 36 in the original two matrix converter based topology [1]. In this arrangement, a 6-switch converter is connected to the grid followed by two inverters that are connected to the stator windings of an open-end machine. The two inverters operate in phase opposition and they are controlled such that the common-mode voltage across each machine phase is zero. Also, the common-mode voltage switching at the machine terminals is eliminated. The input phase currents have 120-degree-conduction and thus have low order harmonics with unity displacement-power-factor (DPF). A low input current THD scheme is proposed for applications where multiple electric drives are connected to the grid.","PeriodicalId":91410,"journal":{"name":"Summer Computer Simulation Conference : (SCSC 2014) : 2014 Summer Simulation Multi-Conference : Monterey, California, USA, 6-10 July 2014. Summer Computer Simulation Conference (2014 : Monterey, Calif.)","volume":"49 1","pages":"118-123"},"PeriodicalIF":0.0000,"publicationDate":"2007-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Summer Computer Simulation Conference : (SCSC 2014) : 2014 Summer Simulation Multi-Conference : Monterey, California, USA, 6-10 July 2014. Summer Computer Simulation Conference (2014 : Monterey, Calif.)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/1357910.1357929","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6
Abstract
A PEBB-based direct-link converter arrangement for the control of an open-ended three-phase machine is analyzed in this paper. The converter arrangement requires only 18 unidirectional switches as compared to 36 in the original two matrix converter based topology [1]. In this arrangement, a 6-switch converter is connected to the grid followed by two inverters that are connected to the stator windings of an open-end machine. The two inverters operate in phase opposition and they are controlled such that the common-mode voltage across each machine phase is zero. Also, the common-mode voltage switching at the machine terminals is eliminated. The input phase currents have 120-degree-conduction and thus have low order harmonics with unity displacement-power-factor (DPF). A low input current THD scheme is proposed for applications where multiple electric drives are connected to the grid.