Effect of Two Denture Teeth Materials on Masticatory Efficiency, Wear, Bonding to Denture Base

Mahaa Ahmed, Hala Gamal El-Din, S. Kabeel
{"title":"Effect of Two Denture Teeth Materials on Masticatory Efficiency, Wear, Bonding to Denture Base","authors":"Mahaa Ahmed, Hala Gamal El-Din, S. Kabeel","doi":"10.21608/adjg.2021.42852.1295","DOIUrl":null,"url":null,"abstract":"Purpose: This study compared between nano composite denture teeth and IPN crosslinked acrylic teeth regarding masticatory efficiency and some mechanical properties (wear, micro tensile bonding strength to denture base). Material and methods: Ten completely edentulous patients with ages ranging from 55-60 years were selected. Each patient received two dentures made from heat-cured acrylic resin , One with IPN crosslinked acrylic teeth and the other with nano composite teeth. Masticatory efficiency was evaluated for each patient at the time of insertion of the dentures and one month later. Laboratory study: For testing wear, thirty specimens were constructed and divided into two groups. Fifteen IPN cross-linked acrylic teeth (Group І) and Fifteen nano composite denture teeth (Group ІІ). For testing Micro tensile bonding strength, Twelve specimens were constructed of artificial teeth together with the heat-cured acrylic resin bases, These specimens were fixed to a microsawing machine and cut into one hundred and twenty micro beam samples which were then divided into two groups; sixty beams of IPN cross-linked acrylic teeth (Group І) and sixty beams of nano composite denture teeth (Group ІІ). Results: The results revealed no statistical significant differences (p ≤ 0.05) as indicated by paired t-test between IPN cross-linked acrylic teeth and nano composite teeth in masticatory efficiency, wear, and micro tensile bonding strength to the denture base. Conclusions: In comparison to IPN cross-linked acrylic teeth, nano composite denture teeth showed non-significant difference regarding masticatory efficiency, wear resistance, and micro tensile bonding strength to the denture base. Codex : 02/22.01 azhardentj@azhar.edu.eg http://adjg.journals.ekb.eg DOI: 10.21608/adjg.2021.42852.1295 Restorative Dentistry (Removable Prosthodontics, Fixed Prosthodontics, Endodontics, Dental Biomaterials, Operative Dentistry)","PeriodicalId":7493,"journal":{"name":"Al-Azhar Dental Journal for Girls","volume":"20 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Al-Azhar Dental Journal for Girls","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21608/adjg.2021.42852.1295","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This study compared between nano composite denture teeth and IPN crosslinked acrylic teeth regarding masticatory efficiency and some mechanical properties (wear, micro tensile bonding strength to denture base). Material and methods: Ten completely edentulous patients with ages ranging from 55-60 years were selected. Each patient received two dentures made from heat-cured acrylic resin , One with IPN crosslinked acrylic teeth and the other with nano composite teeth. Masticatory efficiency was evaluated for each patient at the time of insertion of the dentures and one month later. Laboratory study: For testing wear, thirty specimens were constructed and divided into two groups. Fifteen IPN cross-linked acrylic teeth (Group І) and Fifteen nano composite denture teeth (Group ІІ). For testing Micro tensile bonding strength, Twelve specimens were constructed of artificial teeth together with the heat-cured acrylic resin bases, These specimens were fixed to a microsawing machine and cut into one hundred and twenty micro beam samples which were then divided into two groups; sixty beams of IPN cross-linked acrylic teeth (Group І) and sixty beams of nano composite denture teeth (Group ІІ). Results: The results revealed no statistical significant differences (p ≤ 0.05) as indicated by paired t-test between IPN cross-linked acrylic teeth and nano composite teeth in masticatory efficiency, wear, and micro tensile bonding strength to the denture base. Conclusions: In comparison to IPN cross-linked acrylic teeth, nano composite denture teeth showed non-significant difference regarding masticatory efficiency, wear resistance, and micro tensile bonding strength to the denture base. Codex : 02/22.01 azhardentj@azhar.edu.eg http://adjg.journals.ekb.eg DOI: 10.21608/adjg.2021.42852.1295 Restorative Dentistry (Removable Prosthodontics, Fixed Prosthodontics, Endodontics, Dental Biomaterials, Operative Dentistry)
两种义齿材料对咀嚼效率、磨损、与义齿基托结合的影响
目的:比较纳米复合义齿与IPN交联丙烯酸义齿的咀嚼效率和一些力学性能(磨损、与义齿基托的微拉伸结合强度)。材料与方法:选择年龄55 ~ 60岁的全牙无牙患者10例。每例患者接受两颗热固化丙烯酸树脂义齿,一颗为IPN交联丙烯酸树脂义齿,另一颗为纳米复合树脂义齿。分别在植入义齿时和1个月后对患者的咀嚼效率进行评估。实验室研究:为了测试磨损,制作了30个试样,分为两组。15颗IPN交联丙烯酸牙(组І)和15颗纳米复合义齿(组ІІ)。为了测试微拉伸结合强度,将12个假牙与热固化的丙烯酸树脂底座一起制成试样,将试样固定在微锯床上,切割成120个微梁试样,分成两组;IPN交联丙烯酸牙60根(І组)和纳米复合义齿60根(ІІ组)。结果:经配对t检验,IPN交联丙烯酸牙与纳米复合牙在咀嚼效率、磨损、与义齿基托的微拉伸结合强度方面差异无统计学意义(p≤0.05)。结论:纳米复合义齿与IPN交联丙烯酸齿相比,在咀嚼效率、耐磨性、与义齿基托的微拉伸结合强度等方面均无显著差异。法典:02/22.01 azhardentj@azhar.edu.eg http://adjg.journals.ekb.eg DOI: 10.21608/adjg.2021.42852.1295修复牙科(可移动修复学,固定修复学,牙髓学,牙科生物材料,牙科手术)
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信