Serum Creatinine Determination: Comparison between Colorimetric (Jaffé) and Enzymatic Methods in Renal Transplant Recipients

Houda Kouame, Mohammed Benamo-Seghir, Ayoub Samih, Asmaa Morjan, Nabiha Kamal
{"title":"Serum Creatinine Determination: Comparison between Colorimetric (Jaffé) and Enzymatic Methods in Renal Transplant Recipients","authors":"Houda Kouame, Mohammed Benamo-Seghir, Ayoub Samih, Asmaa Morjan, Nabiha Kamal","doi":"10.9734/ajbgmb/2023/v14i3314","DOIUrl":null,"url":null,"abstract":"Background: Serum creatinine is the most requested parameter in current practice in the context of functional exploration of the kidney. Its contribution to medical care is particularly decisive for kidney transplant patients. The aim of the study is to compare the colorimetric and enzymatic techniques available in our laboratory for the determination of creatinine in samples from kidney transplant patients. \nMethods: Prospective study carried out at the Biochemistry laboratory of the University Hospital Center (CHU) Ibn Rochd in Casablanca Morocco, over a period of 8 months, carried out on a series of 45 samples from kidney transplant patients who simultaneously benefited from a creatinine assay by colorimetric and enzymatic techniques. The samples were taken on dry tubes and analyzed on the Alinity ® Abbott analyzer. The statistical study of correlation was made by the SPSS software with calculation of the p-value and the coefficient of Pearson (r). \nResults: During the study period 45 samples were collected. Seventy percent of the prescriptions came from the Nephrology Department. The mean serum creatinine value by enzymatic technique was 39.04 ± 11.7 mg/l, and by colorimetric technique 38.24 ± 12.4 mg/l. The creatinine level by the two techniques was pathological in 69% of cases and normal in 31%. The correlation between the serum creatinine assay by enzymatic Versus colorimetric technique is positive with r=0.994 and P-value<0.001. \nConclusion: According to literature, colorimetric techniques are sensitive to interference with pseudochromogenic substances, while enzymatic techniques are standardized due to their specificity and performance but remain more expensive. In our study the correlation between the two techniques was positive with a correlation equation: (y = 0.82 + 1*x). According to our results, no significant difference between the two techniques was observed in our laboratory.","PeriodicalId":8498,"journal":{"name":"Asian Journal of Biochemistry, Genetics and Molecular Biology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-06-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Biochemistry, Genetics and Molecular Biology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.9734/ajbgmb/2023/v14i3314","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Serum creatinine is the most requested parameter in current practice in the context of functional exploration of the kidney. Its contribution to medical care is particularly decisive for kidney transplant patients. The aim of the study is to compare the colorimetric and enzymatic techniques available in our laboratory for the determination of creatinine in samples from kidney transplant patients. Methods: Prospective study carried out at the Biochemistry laboratory of the University Hospital Center (CHU) Ibn Rochd in Casablanca Morocco, over a period of 8 months, carried out on a series of 45 samples from kidney transplant patients who simultaneously benefited from a creatinine assay by colorimetric and enzymatic techniques. The samples were taken on dry tubes and analyzed on the Alinity ® Abbott analyzer. The statistical study of correlation was made by the SPSS software with calculation of the p-value and the coefficient of Pearson (r). Results: During the study period 45 samples were collected. Seventy percent of the prescriptions came from the Nephrology Department. The mean serum creatinine value by enzymatic technique was 39.04 ± 11.7 mg/l, and by colorimetric technique 38.24 ± 12.4 mg/l. The creatinine level by the two techniques was pathological in 69% of cases and normal in 31%. The correlation between the serum creatinine assay by enzymatic Versus colorimetric technique is positive with r=0.994 and P-value<0.001. Conclusion: According to literature, colorimetric techniques are sensitive to interference with pseudochromogenic substances, while enzymatic techniques are standardized due to their specificity and performance but remain more expensive. In our study the correlation between the two techniques was positive with a correlation equation: (y = 0.82 + 1*x). According to our results, no significant difference between the two techniques was observed in our laboratory.
肾移植受者血清肌酐测定:比色法与酶法的比较
背景:血清肌酐是目前肾脏功能探查中最需要的参数。它对医疗保健的贡献对肾移植患者尤其具有决定性。本研究的目的是比较我们实验室可用的比色法和酶法测定肾移植患者样本中的肌酐。方法:在摩洛哥卡萨布兰卡大学医院中心(CHU) Ibn Rochd生物化学实验室进行了为期8个月的前瞻性研究,对肾移植患者的45份样本进行了一系列研究,这些患者同时受益于比色法和酶技术的肌酐测定。样品在干管上采集,并在Alinity®Abbott分析仪上进行分析。采用SPSS软件进行相关性统计研究,计算p值和Pearson (r)系数。结果:研究期间共收集样本45份。70%的处方来自肾脏病科。酶法测定血清肌酐平均值为39.04±11.7 mg/l,比色法测定血清肌酐平均值为38.24±12.4 mg/l。两种方法测定的肌酐水平69%为病理,31%为正常。酶法测定血清肌酐与比色法测定血清肌酐呈正相关(r=0.994, p值<0.001)。结论:根据文献,比色法技术对假显色物质的干扰敏感,而酶法技术由于其特异性和性能而标准化,但成本较高。在我们的研究中,两种技术之间呈正相关,相关方程为(y = 0.82 + 1*x)。根据我们的结果,在我们的实验室中没有观察到两种技术之间的显着差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信