In silico analysis of optimum photon energy spectra and beam parameters for iodine nanoparticle–aided orthovoltage radiation therapy of brain tumors

IF 1.3 4区 工程技术 Q4 COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS
A. Mesbahi, Maryam Sadeghian, Aisan Mesbahi, H. Smilowitz, J. Hainfeld
{"title":"In silico analysis of optimum photon energy spectra and beam parameters for iodine nanoparticle–aided orthovoltage radiation therapy of brain tumors","authors":"A. Mesbahi, Maryam Sadeghian, Aisan Mesbahi, H. Smilowitz, J. Hainfeld","doi":"10.1177/00375497221135630","DOIUrl":null,"url":null,"abstract":"In this study, the effect of photon energy spectra on the dose enhancement factor (DEF) and other influencing parameters such as skull–tumor dose ratios were estimated for a confined tumor loaded with iodine nanoparticles (INPs). A mathematical brain phantom with a brain tumor was simulated by the MCNP6 Monte Carlo code. A validated commercial computed tomography model consisting of an X-ray tube, Al–Cu filters, and collimators was used to simulate the rotational conformal treatment of the tumor. INPs with a diameter of 20 nm and concentrations of 10–50 mg/g were introduced inside the tumor as homogenously distributed spherical particles. The dose distribution inside the phantom was scored for several orthovoltage beams with the peak voltages of 140, 200, and 320 kVp as well as two 3.5 and 6 MV megavoltage beams. A significant rise of DEF values with nanoparticle (NP) concentration for orthovoltage beams is revealed; no significant dose enhancement was obtained for megavoltage beams. The highest DEF and skull–tumor dose ratio were obtained for the 140 kVp beam which decreased with the number of directional fields. The clinically optimal plan for a brain tumor, with high DEFs of 2.81–2.24 and acceptable skull–tumor dose ratios of 0.61–0.51, would be feasible for treatment using 200 and 320 kVp beams, an iodine concentration of 20 mg/g, and 8–15 fields. Our calculations show that clinically significant radiation dose enhancements can be obtained for tumors loaded with INPs using orthovoltage beams. Optimal treatment regimens are feasible using a proper selection of photon beam spectrum and sufficient numbers of cross-firing beams. The limiting effect of skull bone could be minimized by increasing the number of radiation fields and the use of higher quality of orthovoltage beams.","PeriodicalId":49516,"journal":{"name":"Simulation-Transactions of the Society for Modeling and Simulation International","volume":"16 1","pages":"539 - 552"},"PeriodicalIF":1.3000,"publicationDate":"2022-11-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Simulation-Transactions of the Society for Modeling and Simulation International","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/00375497221135630","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS","Score":null,"Total":0}
引用次数: 0

Abstract

In this study, the effect of photon energy spectra on the dose enhancement factor (DEF) and other influencing parameters such as skull–tumor dose ratios were estimated for a confined tumor loaded with iodine nanoparticles (INPs). A mathematical brain phantom with a brain tumor was simulated by the MCNP6 Monte Carlo code. A validated commercial computed tomography model consisting of an X-ray tube, Al–Cu filters, and collimators was used to simulate the rotational conformal treatment of the tumor. INPs with a diameter of 20 nm and concentrations of 10–50 mg/g were introduced inside the tumor as homogenously distributed spherical particles. The dose distribution inside the phantom was scored for several orthovoltage beams with the peak voltages of 140, 200, and 320 kVp as well as two 3.5 and 6 MV megavoltage beams. A significant rise of DEF values with nanoparticle (NP) concentration for orthovoltage beams is revealed; no significant dose enhancement was obtained for megavoltage beams. The highest DEF and skull–tumor dose ratio were obtained for the 140 kVp beam which decreased with the number of directional fields. The clinically optimal plan for a brain tumor, with high DEFs of 2.81–2.24 and acceptable skull–tumor dose ratios of 0.61–0.51, would be feasible for treatment using 200 and 320 kVp beams, an iodine concentration of 20 mg/g, and 8–15 fields. Our calculations show that clinically significant radiation dose enhancements can be obtained for tumors loaded with INPs using orthovoltage beams. Optimal treatment regimens are feasible using a proper selection of photon beam spectrum and sufficient numbers of cross-firing beams. The limiting effect of skull bone could be minimized by increasing the number of radiation fields and the use of higher quality of orthovoltage beams.
碘纳米粒子辅助正电压放射治疗脑肿瘤的最佳光子能谱和光束参数的硅分析
在这项研究中,光子能量谱对剂量增强因子(DEF)和其他影响参数(如颅底肿瘤剂量比)的影响,如负载碘纳米颗粒(INPs)的局限肿瘤。用MCNP6蒙特卡罗代码模拟了一个带有脑瘤的数学脑幻影。一个由x射线管、Al-Cu滤光片和准直器组成的商业计算机断层扫描模型被用来模拟肿瘤的旋转适形治疗。将直径为20 nm,浓度为10-50 mg/g的INPs以均匀分布的球形颗粒导入肿瘤内。对峰值电压分别为140kvp、200kvp和320kvp的几束正压波束以及两束3.5和6mv的巨压波束在模体内的剂量分布进行了评分。正交电压光束的DEF值随纳米粒子(NP)浓度的增加而显著升高;对超高压光束没有明显的剂量增强。在140 kVp时,靶区DEF和头盖骨肿瘤剂量比最高,随方向场数的增加而减小。临床上对脑肿瘤的最佳治疗方案是,高DEFs为2.81-2.24,可接受的颅脑肿瘤剂量比为0.61-0.51,使用200和320 kVp光束,碘浓度为20 mg/g, 8-15场治疗是可行的。我们的计算表明,使用正电压光束可以对负载INPs的肿瘤获得临床显著的辐射剂量增强。只要选择合适的光子波谱和足够数量的交叉发射光束,最佳治疗方案是可行的。通过增加辐射场的数量和使用高质量的正电压光束,可以最大限度地减少颅骨的限制效应。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.50
自引率
31.20%
发文量
60
审稿时长
3 months
期刊介绍: SIMULATION is a peer-reviewed journal, which covers subjects including the modelling and simulation of: computer networking and communications, high performance computers, real-time systems, mobile and intelligent agents, simulation software, and language design, system engineering and design, aerospace, traffic systems, microelectronics, robotics, mechatronics, and air traffic and chemistry, physics, biology, medicine, biomedicine, sociology, and cognition.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信