Asymmetrical half-bridge converter with reduced DC-offset current in transformer

J. Baek, Jaewon Choi, Yeonho Jeong, Yujin Jang, G. Moon, Chanhun Yu
{"title":"Asymmetrical half-bridge converter with reduced DC-offset current in transformer","authors":"J. Baek, Jaewon Choi, Yeonho Jeong, Yujin Jang, G. Moon, Chanhun Yu","doi":"10.1109/IPEMC.2016.7512648","DOIUrl":null,"url":null,"abstract":"In this paper, a new asymmetrical half-bridge converter with reduced DC-offset current in transformer is proposed. In general, to meet the hold-up time conditions, the conventional asymmetrical half-bridge (AHB) converter operates in wide-input-voltage range. Wide-input-voltage range design makes converter suffered from severe asymmetric operation under the nominal operation, which increases the DC-offset current in the transformer, size of the transformer, and unbalance of the voltage stresses of the secondary rectifiers. On the other hand, the proposed converter can reduce the DC-offset current in the transformer and relieve the unbalanced voltage stresses of the secondary rectifiers under the nominal operation by changing transformer turns-ratio with an auxiliary switch and capacitor. Therefore, the proposed converter can achieve high efficiency. The validity of the proposed converter is confirmed by experimental results from a prototype with 330-400V input, 300W/12V output.","PeriodicalId":6857,"journal":{"name":"2016 IEEE 8th International Power Electronics and Motion Control Conference (IPEMC-ECCE Asia)","volume":"112 1","pages":"2249-2253"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE 8th International Power Electronics and Motion Control Conference (IPEMC-ECCE Asia)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPEMC.2016.7512648","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

In this paper, a new asymmetrical half-bridge converter with reduced DC-offset current in transformer is proposed. In general, to meet the hold-up time conditions, the conventional asymmetrical half-bridge (AHB) converter operates in wide-input-voltage range. Wide-input-voltage range design makes converter suffered from severe asymmetric operation under the nominal operation, which increases the DC-offset current in the transformer, size of the transformer, and unbalance of the voltage stresses of the secondary rectifiers. On the other hand, the proposed converter can reduce the DC-offset current in the transformer and relieve the unbalanced voltage stresses of the secondary rectifiers under the nominal operation by changing transformer turns-ratio with an auxiliary switch and capacitor. Therefore, the proposed converter can achieve high efficiency. The validity of the proposed converter is confirmed by experimental results from a prototype with 330-400V input, 300W/12V output.
变压器直流偏置电流减小的非对称半桥变换器
本文提出了一种减小变压器直流偏置电流的新型非对称半桥变换器。一般来说,为了满足保持时间条件,传统的非对称半桥变换器工作在宽输入电压范围内。宽输入电压范围的设计使变流器在标称运行下存在严重的不对称运行,增加了变压器内的直流偏置电流,增大了变压器的体积,增加了二次整流器电压应力的不平衡。另一方面,该变流器通过辅助开关和辅助电容改变变压器的匝比,可以减小变压器内的直流偏置电流,缓解二次整流器在标称运行下的电压不平衡应力。因此,所提出的变换器可以达到较高的效率。通过330 ~ 400v输入、300W/12V输出的样机实验结果,验证了所提变换器的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信