A novel computed tomography-based three-column MLP classification of intertrochanteric fracture.

IF 0.7 Q4 MEDICINE, RESEARCH & EXPERIMENTAL
Qi-Long Jiang, Yan Li, Xin-Wen Bai, Yu Deng, Hao Hong, Jun Li, Yong Cao, Xiao-Yu Peng
{"title":"A novel computed tomography-based three-column MLP classification of intertrochanteric fracture.","authors":"Qi-Long Jiang, Yan Li, Xin-Wen Bai, Yu Deng, Hao Hong, Jun Li, Yong Cao, Xiao-Yu Peng","doi":"10.2152/jmi.70.524","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The aim of the present study was to introduce a novel three-dimensional computed tomography (3DCT)-based three-column classification (named \"MLP classification system\") of intertrochanteric fractures and evaluate its reproducibility and reliability.</p><p><strong>Methods: </strong>From September 2020 to September 2022, a total of 258 consecutive patients (60 male, 198 female;mean age 81.3 years) with intertrochanteric fractures were included in this study. The fracture in each case was assessed using a novel three-dimensional computed tomography-based three-column classification. Two examiners tested the intra and inter-observer reliability of this new classification system using kappa variance.</p><p><strong>Results: </strong>The intertrochanteric region was divided into the medial column, lateral column, and posterior column. Intertrochanteric fractures were documented as M0/1/2L0/1/2/3P0/1/2/3. All fractures were classifiable into the new classification system. The intra-observer kappa values were 0.91 and 0.89, while the inter-observer kappa value was 0.82, both indicating almost perfect reliability.</p><p><strong>Conclusion: </strong>This novel 3DCT-based MLP classification system for intertrochanteric fractures is comprehensive, and reproducible with good agreement. It is based on proximal femur biomechanic characteristics and traumatic mechanism, contributing to formulating more reasonable treatment protocols involving various late-model internal fixation devices. J. Med. Invest. 70 : 524-529, August, 2023.</p>","PeriodicalId":46910,"journal":{"name":"JOURNAL OF MEDICAL INVESTIGATION","volume":null,"pages":null},"PeriodicalIF":0.7000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JOURNAL OF MEDICAL INVESTIGATION","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2152/jmi.70.524","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: The aim of the present study was to introduce a novel three-dimensional computed tomography (3DCT)-based three-column classification (named "MLP classification system") of intertrochanteric fractures and evaluate its reproducibility and reliability.

Methods: From September 2020 to September 2022, a total of 258 consecutive patients (60 male, 198 female;mean age 81.3 years) with intertrochanteric fractures were included in this study. The fracture in each case was assessed using a novel three-dimensional computed tomography-based three-column classification. Two examiners tested the intra and inter-observer reliability of this new classification system using kappa variance.

Results: The intertrochanteric region was divided into the medial column, lateral column, and posterior column. Intertrochanteric fractures were documented as M0/1/2L0/1/2/3P0/1/2/3. All fractures were classifiable into the new classification system. The intra-observer kappa values were 0.91 and 0.89, while the inter-observer kappa value was 0.82, both indicating almost perfect reliability.

Conclusion: This novel 3DCT-based MLP classification system for intertrochanteric fractures is comprehensive, and reproducible with good agreement. It is based on proximal femur biomechanic characteristics and traumatic mechanism, contributing to formulating more reasonable treatment protocols involving various late-model internal fixation devices. J. Med. Invest. 70 : 524-529, August, 2023.

一种新的基于计算机断层扫描的转子间骨折三列MLP分类方法。
目的:本研究的目的是介绍一种新的基于三维计算机断层扫描(3DCT)的转子间骨折三柱分类(名为“MLP分类系统”),并评估其可重复性和可靠性。方法:自2020年9月至2022年9月,共有258名转子间骨折患者(60名男性,198名女性;平均年龄81.3岁)纳入本研究。每个病例的骨折都使用一种新的基于三列分类的三维计算机断层扫描进行评估。两名检查人员使用kappa方差测试了这种新分类系统的观察者内部和观察者之间的可靠性。结果:股骨粗隆间区分为内侧柱、外侧柱和后柱。转子间骨折记录为M0/1/2L0/1/2/3P0/1/2/3。所有的裂缝都可以分类到新的分类系统中。观察者内部的κ值为0.91和0.89,而观察者之间的κ值则为0.82,这两个值都表明几乎完全可靠。结论:该新的基于3DCT的股骨转子间骨折MLP分类系统综合性强,可重复性好,符合性好。它基于股骨近端生物力学特征和创伤机制,有助于制定更合理的治疗方案,涉及各种新型内固定装置。J.Med.Invest。70:524-5292023年8月。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
JOURNAL OF MEDICAL INVESTIGATION
JOURNAL OF MEDICAL INVESTIGATION MEDICINE, RESEARCH & EXPERIMENTAL-
CiteScore
1.20
自引率
0.00%
发文量
55
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信