Andrew S Haddad, Melissa H Fries, Helain Landy, Priyanka S Tripuraneni, Sara N Iqbal
{"title":"Evaluation of Early Screening for Diabetes Mellitus in Pregnancy with Hemoglobin A1c.","authors":"Andrew S Haddad, Melissa H Fries, Helain Landy, Priyanka S Tripuraneni, Sara N Iqbal","doi":"10.1055/s-0043-1776150","DOIUrl":null,"url":null,"abstract":"<p><p>Early diabetes screening is recommended for high-risk pregnant women risk via a 1-hour glucose challenge test (1-hour GCT). Hemoglobin A1c (HbA1c) can be obtained with initial obstetric laboratories. We sought to examine the relationship between HbA1c and 1-hour GCT for early diabetes screening in pregnancy. This is a retrospective cohort study of 204 high-risk pregnant women who underwent early HbA1c and 1-hour GCT. Simple logistic regression analysis was performed to predict abnormal 1-hour GCT and diagnosis of diabetes using HbA1c. A total of 158 (77.5%), 44 (21.5%), and 2 (1%) women had HbA1c of less than 5.7, 5.7 to 6.4, and 6.5% or higher, respectively. Seven of 158 (4.4%) women with HbA1c less than 5.7% and 8 of 44 (18.2%) with HbA1c of 5.7 to 6.4% had a diagnosis of diabetes. A positive correlation between early HbA1c and 1-hour GCT was detected. Logistic regression showed HbA1c significantly predicted the risk of diabetes but was not a good predictor of abnormal 1-hour GCT. HbA1c of 5.5% or less had a 97% or higher negative predictive value for early diabetes in pregnancy. There is a positive correlation between HbA1c and 1-hour GCT for the early screening of diabetes in pregnancy. Women with early HbA1c ≤ 5.5% could forego further testing in early pregnancy.</p>","PeriodicalId":7645,"journal":{"name":"AJP Reports","volume":"13 4","pages":"e71-e77"},"PeriodicalIF":0.8000,"publicationDate":"2023-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10630085/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"AJP Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0043-1776150","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/7/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"PEDIATRICS","Score":null,"Total":0}
引用次数: 0
Abstract
Early diabetes screening is recommended for high-risk pregnant women risk via a 1-hour glucose challenge test (1-hour GCT). Hemoglobin A1c (HbA1c) can be obtained with initial obstetric laboratories. We sought to examine the relationship between HbA1c and 1-hour GCT for early diabetes screening in pregnancy. This is a retrospective cohort study of 204 high-risk pregnant women who underwent early HbA1c and 1-hour GCT. Simple logistic regression analysis was performed to predict abnormal 1-hour GCT and diagnosis of diabetes using HbA1c. A total of 158 (77.5%), 44 (21.5%), and 2 (1%) women had HbA1c of less than 5.7, 5.7 to 6.4, and 6.5% or higher, respectively. Seven of 158 (4.4%) women with HbA1c less than 5.7% and 8 of 44 (18.2%) with HbA1c of 5.7 to 6.4% had a diagnosis of diabetes. A positive correlation between early HbA1c and 1-hour GCT was detected. Logistic regression showed HbA1c significantly predicted the risk of diabetes but was not a good predictor of abnormal 1-hour GCT. HbA1c of 5.5% or less had a 97% or higher negative predictive value for early diabetes in pregnancy. There is a positive correlation between HbA1c and 1-hour GCT for the early screening of diabetes in pregnancy. Women with early HbA1c ≤ 5.5% could forego further testing in early pregnancy.