An in vivo study to assess and compare the angular, linear, and depth deviation as well as the difference in bone density of implants placed using computer-aided design/computer-aided manufacturing fabricated three-dimensional guides versus the implants placed using bone pen kit in maxillary and mandibular ridges.

IF 1 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
Shipra Aggarwal, Sumit Aggarwal, Roma Goswami, Apoorva Mowar, Nitin Tomar, Deepesh Saxena
{"title":"An <i>in vivo</i> study to assess and compare the angular, linear, and depth deviation as well as the difference in bone density of implants placed using computer-aided design/computer-aided manufacturing fabricated three-dimensional guides versus the implants placed using bone pen kit in maxillary and mandibular ridges.","authors":"Shipra Aggarwal, Sumit Aggarwal, Roma Goswami, Apoorva Mowar, Nitin Tomar, Deepesh Saxena","doi":"10.4103/jips.jips_193_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>The aim is to assess and compare angular, linear, and depth deviation and difference in bone density of dental implants placed using computer aided design/computer aided manufacturing (CAD/CAM) fabricated surgical guides versus implants placed using Bone Pen Kit. Till now, no original research exists in the search engines such as Pubmed, Google Scholar, Science Direct, and Research Gate on this kit.</p><p><strong>Settings and design: </strong>In vivo- Randomised control trial.</p><p><strong>Materials and methods: </strong>Twenty clinical cases were selected and split into two distinct groups. Group 1 involved the placement of 10 implants using CAD/CAM fabricated three dimensional guides and Group 2 involved the placement of 10 implants using Bone Pen Kit. Four deviation parameters were evaluated, which included: (a) Angular deviation, (b) Linear deviation at implant platform, (c) Linear deviation at implant apex, and (d) Depth deviation and difference in bone density before and after implant placement was also evaluated.</p><p><strong>Statistical analysis used: </strong>SPSS software version 23 was utilized for the analysis of the data. The comparison was made using the Whitney test, and Wilcoxon signed rank test.</p><p><strong>Results: </strong>When comparing angular deviation, the results indicated a statistically significant difference with a P < 0.05. The values observed for angular and linear deviation in Group 2 were significantly greater than those in Group 1. No statistically significant difference in depth and linear deviation was found at the implant platform among the two groups. Bone density before and after implant placement was significantly higher in Group 1.</p><p><strong>Conclusions: </strong>(1) Angular and linear deviation at the apex in Group 2 exhibited higher values in comparison to Group 1, (2) No difference in depth and linear deviation at the implant platform was found among the two groups, and (3) There was no difference in change in bone density among two groups.</p>","PeriodicalId":22669,"journal":{"name":"The Journal of Indian Prosthodontic Society","volume":"23 3","pages":"266-276"},"PeriodicalIF":1.0000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10467322/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of Indian Prosthodontic Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jips.jips_193_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: The aim is to assess and compare angular, linear, and depth deviation and difference in bone density of dental implants placed using computer aided design/computer aided manufacturing (CAD/CAM) fabricated surgical guides versus implants placed using Bone Pen Kit. Till now, no original research exists in the search engines such as Pubmed, Google Scholar, Science Direct, and Research Gate on this kit.

Settings and design: In vivo- Randomised control trial.

Materials and methods: Twenty clinical cases were selected and split into two distinct groups. Group 1 involved the placement of 10 implants using CAD/CAM fabricated three dimensional guides and Group 2 involved the placement of 10 implants using Bone Pen Kit. Four deviation parameters were evaluated, which included: (a) Angular deviation, (b) Linear deviation at implant platform, (c) Linear deviation at implant apex, and (d) Depth deviation and difference in bone density before and after implant placement was also evaluated.

Statistical analysis used: SPSS software version 23 was utilized for the analysis of the data. The comparison was made using the Whitney test, and Wilcoxon signed rank test.

Results: When comparing angular deviation, the results indicated a statistically significant difference with a P < 0.05. The values observed for angular and linear deviation in Group 2 were significantly greater than those in Group 1. No statistically significant difference in depth and linear deviation was found at the implant platform among the two groups. Bone density before and after implant placement was significantly higher in Group 1.

Conclusions: (1) Angular and linear deviation at the apex in Group 2 exhibited higher values in comparison to Group 1, (2) No difference in depth and linear deviation at the implant platform was found among the two groups, and (3) There was no difference in change in bone density among two groups.

一项体内研究,旨在评估和比较使用计算机辅助设计/计算机辅助制造制造的三维导向器放置的植入物与使用骨笔套件放置在上颌和下颌嵴的植入物的角度、线性和深度偏差以及骨密度差异。
目的:目的是评估和比较使用计算机辅助设计/计算机辅助制造(CAD/CAM)制造的外科引导器放置的牙科植入物与使用骨笔套件放置的植入物的角度、线性和深度偏差以及骨密度差异。到目前为止,在Pubmed、Google Scholar、Science Direct和research Gate等搜索引擎中,还没有关于该工具包的原始研究。设置和设计:体内-随机对照试验。材料和方法:选择20例临床病例,分为两组。第1组使用CAD/CAM制造的三维导向器放置10个植入物,第2组使用Bone Pen Kit放置10个种植物。评估了四个偏差参数,包括:(a)角度偏差,(b)植入物平台的线性偏差,(c)植入物顶点的线性偏差和(d)植入物放置前后的深度偏差和骨密度差异。统计分析采用SPSS软件23版进行数据分析。使用Whitney检验和Wilcoxon符号秩检验进行比较。结果:当比较角度偏差时,结果显示有统计学意义的差异,P<0.05。在第2组中观察到的角度和线性偏差的值显著大于在第1组中的值。两组植入物平台的深度和线性偏差无统计学显著差异。第1组植入前后的骨密度显著高于第1组。结论:(1)与第1组相比,第2组的根尖角度和线性偏差值更高;(2)两组植入平台的深度和线性偏差没有差异;(3)两组的骨密度变化没有差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
The Journal of Indian Prosthodontic Society
The Journal of Indian Prosthodontic Society DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.20
自引率
8.30%
发文量
26
审稿时长
20 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信