{"title":"Association of Scalp High-Frequency Oscillation Detection and Characteristics With Disease Activity in Pediatric Epilepsy.","authors":"Keisuke Maeda, Nami Hosoda, Junichi Fukumoto, Shun Kawai, Mizuki Hayafuji, Himari Tsuboi, Shiho Fujita, Naohiro Ichino, Keisuke Osakabe, Keiko Sugimoto, Naoko Ishihara","doi":"10.1097/WNP.0000000000001052","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>High-frequency oscillation (HFO) in scalp electroencephalography is a promising new noninvasive prognostic epilepsy biomarker, but further data are needed to ascertain the utility of this parameter. The present work investigated the association between epileptic activity and scalp HFO in pediatric patients with various types of epilepsy, using multivariable regression models to correct for possible confounding factors.</p><p><strong>Methods: </strong>The authors analyzed 97 subjects who were divided into groups with active epilepsy (within 1 year of seizure), seizure-free epilepsy (>1 year without seizure), and nonepilepsy. Regarding the frequency of seizure occurrence as an indicator of epileptic activity, we categorized subjects into four groups (Daily/Weekly, Monthly, Yearly, and Rarely).</p><p><strong>Results: </strong>Multiple linear regression analysis showed that the scalp HFO detection rate was significantly higher in patients with active epilepsy than in those with nonepilepsy (β [95% confidence interval] = 2.77 [1.79-4.29]; P < 0.001). The association between scalp HFO detection rate and frequency of seizure occurrence was highest in the Daily/Weekly group (β [95% confidence interval] = 3.38 [1.57-7.27]; P = 0.002), followed by Monthly and Yearly groups (β [95% confidence interval] = 2.42 [1.02-5.73]; P = 0.046 and 0.36 [0.16-0.83]; P = 0.017). In addition, HFO duration, number of peaks, and number of channels detected were significantly higher in patients with active epilepsy.</p><p><strong>Conclusions: </strong>Pediatric patients with active epilepsy and high frequency of seizure occurrence exhibited a higher scalp HFO detection rate. These results may help to establish HFO detectable by noninvasive scalp electroencephalography as a biomarker of active epilepsy in pediatric patients.</p>","PeriodicalId":15516,"journal":{"name":"Journal of Clinical Neurophysiology","volume":" ","pages":"28-35"},"PeriodicalIF":2.3000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Neurophysiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/WNP.0000000000001052","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/10/30 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: High-frequency oscillation (HFO) in scalp electroencephalography is a promising new noninvasive prognostic epilepsy biomarker, but further data are needed to ascertain the utility of this parameter. The present work investigated the association between epileptic activity and scalp HFO in pediatric patients with various types of epilepsy, using multivariable regression models to correct for possible confounding factors.
Methods: The authors analyzed 97 subjects who were divided into groups with active epilepsy (within 1 year of seizure), seizure-free epilepsy (>1 year without seizure), and nonepilepsy. Regarding the frequency of seizure occurrence as an indicator of epileptic activity, we categorized subjects into four groups (Daily/Weekly, Monthly, Yearly, and Rarely).
Results: Multiple linear regression analysis showed that the scalp HFO detection rate was significantly higher in patients with active epilepsy than in those with nonepilepsy (β [95% confidence interval] = 2.77 [1.79-4.29]; P < 0.001). The association between scalp HFO detection rate and frequency of seizure occurrence was highest in the Daily/Weekly group (β [95% confidence interval] = 3.38 [1.57-7.27]; P = 0.002), followed by Monthly and Yearly groups (β [95% confidence interval] = 2.42 [1.02-5.73]; P = 0.046 and 0.36 [0.16-0.83]; P = 0.017). In addition, HFO duration, number of peaks, and number of channels detected were significantly higher in patients with active epilepsy.
Conclusions: Pediatric patients with active epilepsy and high frequency of seizure occurrence exhibited a higher scalp HFO detection rate. These results may help to establish HFO detectable by noninvasive scalp electroencephalography as a biomarker of active epilepsy in pediatric patients.
期刊介绍:
The Journal of Clinical Neurophysiology features both topical reviews and original research in both central and peripheral neurophysiology, as related to patient evaluation and treatment.