Characterization of Odorants in an Air Wet Scrubber Using Direct Aqueous Injection-Gas Chromatography-Mass Spectrometry (DAI-GC-MS) and Solid Phase Extraction (SPE-GC)

N. Abu-Khalaf, K. Haselmann
{"title":"Characterization of Odorants in an Air Wet Scrubber Using Direct Aqueous Injection-Gas Chromatography-Mass Spectrometry (DAI-GC-MS) and Solid Phase Extraction (SPE-GC)","authors":"N. Abu-Khalaf, K. Haselmann","doi":"10.5923/J.AJEE.20120203.04","DOIUrl":null,"url":null,"abstract":"One of the biological methods to reduce odours emission from livestock buildings is bioscrubber. Characteri- zation (identification and quantification) of key odorants from an air wet scrubber in livestock buildings is presented. The key odorants represent five chemical groups, i.e. sulphides, alcohols, volatile fatty acids (VFAs), phenols and indoles. Direct aqueous injection (DAI) and solid phase extraction (SPE) methods were used for sample preparation before injecting the samples into the gas chromatography. Gas chromatography-flame ionization detection (GC-FID) was used for identification and quantification of samples prepared by DAI and SPE. The SPE method had a high recovery (i.e. 89-100%). However, DAI showed a better linearity, a lower limit of detection (LOD) and a lower limit of quantification (LOQ) than the SPE method. The DAI method was preferred for identification and quantification as it is cheaper, easier to handle, without sample prep- aration and highly applicable. For at least two odorants, i.e. phenol and 1-butanol, LOD and LOQ were below literature values for odorants detection limits in livestock buildings. Gas chromatography-mass spectrometry (GC-MS) was used to verify the identification of odorants, prepared by DAI, according to their m/z values.","PeriodicalId":92604,"journal":{"name":"American journal of environmental engineering","volume":"2 1","pages":"58-68"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of environmental engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5923/J.AJEE.20120203.04","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

One of the biological methods to reduce odours emission from livestock buildings is bioscrubber. Characteri- zation (identification and quantification) of key odorants from an air wet scrubber in livestock buildings is presented. The key odorants represent five chemical groups, i.e. sulphides, alcohols, volatile fatty acids (VFAs), phenols and indoles. Direct aqueous injection (DAI) and solid phase extraction (SPE) methods were used for sample preparation before injecting the samples into the gas chromatography. Gas chromatography-flame ionization detection (GC-FID) was used for identification and quantification of samples prepared by DAI and SPE. The SPE method had a high recovery (i.e. 89-100%). However, DAI showed a better linearity, a lower limit of detection (LOD) and a lower limit of quantification (LOQ) than the SPE method. The DAI method was preferred for identification and quantification as it is cheaper, easier to handle, without sample prep- aration and highly applicable. For at least two odorants, i.e. phenol and 1-butanol, LOD and LOQ were below literature values for odorants detection limits in livestock buildings. Gas chromatography-mass spectrometry (GC-MS) was used to verify the identification of odorants, prepared by DAI, according to their m/z values.
直接水进-气相色谱-质谱联用(DAI-GC-MS)和固相萃取(SPE-GC)表征空气湿式洗涤器中的气味
生物洗涤器是减少畜舍异味的生物方法之一。介绍了畜舍空气湿式洗涤器中主要气味的表征(识别和定量)。主要气味剂代表五个化学基团,即硫化物、醇、挥发性脂肪酸(VFAs)、酚类和吲哚。采用直接水进样(DAI)和固相萃取(SPE)方法制备样品,然后将样品进气相色谱。采用气相色谱-火焰离子化检测器(GC-FID)对DAI和SPE制备的样品进行鉴定和定量。固相萃取法回收率高(89 ~ 100%)。与固相萃取法相比,DAI具有更好的线性关系、检测下限(LOD)和定量下限(LOQ)。DAI方法具有成本低、操作方便、无需样品制备、适用性强等优点,是鉴定和定量的首选方法。对于至少两种气味剂,即苯酚和1-丁醇,LOD和LOQ低于牲畜舍中气味剂检测极限的文献值。采用气相色谱-质谱联用(GC-MS),根据其m/z值对DAI制备的气味剂进行鉴定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信