Ultrastructural analysis of the surface changes on the nickel-titanium endodontic instruments after multiple use

IF 0.3 Q3 MEDICINE, GENERAL & INTERNAL
Nenad Stošić, J. Popović, Marija Anđelković-Apostolović, A. Mitić, Marija Nikolić, Radomir Barac
{"title":"Ultrastructural analysis of the surface changes on the nickel-titanium endodontic instruments after multiple use","authors":"Nenad Stošić, J. Popović, Marija Anđelković-Apostolović, A. Mitić, Marija Nikolić, Radomir Barac","doi":"10.5937/afmnai38-29386","DOIUrl":null,"url":null,"abstract":"One of the primary goals in endodontics is efficient cleaning and shaping of the root canal while maintaining its original configuration. Numerous studies highlight the advantage of using nickel-titanium instruments and the most important is their high flexibility and the ability to penetrate the curved canals. The aim of this study was to analyze the ultrastructure of the surface of nickel-titanium endodontic files before and after use. Eighty-four instruments were included in this study. The instruments were used one, three and six times for root canal preparation on extracted upper premolars. The analysis was performed based on the number of uses and the size of the instruments. Changes on flat surfaces in the grooves of the instruments, defects of the cutting edges and fractures were evaluated. The surface ultrastructure was analyzed on a scanning electron microscope (SEM). SEM analysis showed irregularities on the surfaces of the new instruments. Surface defects and damage of the cutting edges were present after the first use. After three uses, the damage was more evident in instruments of all sizes. After six uses, all instruments showed damage of the cutting edges, and a significant number of fractures were observed. Irregularities on the working parts are already noticed on the new endodontic instruments and originate from the production process. The first signs of damage appear after the first use. In order to prevent errors in clinical work during root canal preparation, it is recommended that the number of instruments uses should be limited.","PeriodicalId":7132,"journal":{"name":"Acta Facultatis Medicae Naissensis","volume":"1 1","pages":""},"PeriodicalIF":0.3000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Facultatis Medicae Naissensis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5937/afmnai38-29386","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 2

Abstract

One of the primary goals in endodontics is efficient cleaning and shaping of the root canal while maintaining its original configuration. Numerous studies highlight the advantage of using nickel-titanium instruments and the most important is their high flexibility and the ability to penetrate the curved canals. The aim of this study was to analyze the ultrastructure of the surface of nickel-titanium endodontic files before and after use. Eighty-four instruments were included in this study. The instruments were used one, three and six times for root canal preparation on extracted upper premolars. The analysis was performed based on the number of uses and the size of the instruments. Changes on flat surfaces in the grooves of the instruments, defects of the cutting edges and fractures were evaluated. The surface ultrastructure was analyzed on a scanning electron microscope (SEM). SEM analysis showed irregularities on the surfaces of the new instruments. Surface defects and damage of the cutting edges were present after the first use. After three uses, the damage was more evident in instruments of all sizes. After six uses, all instruments showed damage of the cutting edges, and a significant number of fractures were observed. Irregularities on the working parts are already noticed on the new endodontic instruments and originate from the production process. The first signs of damage appear after the first use. In order to prevent errors in clinical work during root canal preparation, it is recommended that the number of instruments uses should be limited.
镍钛根管器械多次使用后表面变化的超微结构分析
牙髓学的主要目标之一是在保持根管原始结构的同时有效地清洁和塑造根管。大量的研究强调了使用镍钛器械的优势,最重要的是它们的高灵活性和穿透弯曲管的能力。本研究的目的是分析镍钛根管锉使用前后表面的超微结构。本研究共纳入84种仪器。分别使用器械1次、3次和6次对拔除的上前磨牙进行根管预备。分析是根据使用次数和仪器的大小进行的。对仪器凹槽平面的变化、切削刃缺陷和断口进行了评价。用扫描电镜对其表面超微结构进行了分析。扫描电镜分析表明,在新仪器的表面不规则。首次使用后出现表面缺陷和切削刃损伤。经过三次使用,各种尺寸的仪器都受到了更明显的损坏。6次使用后,所有器械均出现切削刃损伤,并观察到大量骨折。在新的根管器械上已经注意到工作部件的不规则性,这些不规则性源于生产过程。第一次使用后就会出现损坏的迹象。为了防止临床工作中出现根管预备时的错误,建议限制器械的使用数量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Acta Facultatis Medicae Naissensis
Acta Facultatis Medicae Naissensis MEDICINE, GENERAL & INTERNAL-
CiteScore
0.70
自引率
0.00%
发文量
13
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信