Comparative performance of isolated and fixed-base reinforced concrete structures

Naima Adjou, N. Haddadou
{"title":"Comparative performance of isolated and fixed-base reinforced concrete structures","authors":"Naima Adjou, N. Haddadou","doi":"10.5281/ZENODO.241967","DOIUrl":null,"url":null,"abstract":"The earthquake transmits to the structure a large quantity of energy that causes damage to structures. The seismic isolation technique can absorb a large quantity of the seismic energy. The seismic isolation concept is a new technique in earthquake engineering, its principle is quite simple, and it consists to create a discontinuity between the foundation and the superstructure, so that seismic energy cannot be completely transmitted into the structure.Therefore, this article includes a numerical application of the nonlinear static method, the capacity spectrum method (CSM), on two types of structures, fixed base structure and isolated base structure. The CSM is one of the methods used for the evaluation of seismic performance. Its principle consists in superimposing a curve which represents the capacity of the structure originated from a non-linear static analysis (Pushover), with a curve representing the solicitation brought by the earthquake. The intersection of these two curves represents the point performance, which evaluates the maximum displacement of the structure in the plastic domain.","PeriodicalId":33130,"journal":{"name":"Journal of Building Materials and Structures","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2015-01-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Building Materials and Structures","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5281/ZENODO.241967","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The earthquake transmits to the structure a large quantity of energy that causes damage to structures. The seismic isolation technique can absorb a large quantity of the seismic energy. The seismic isolation concept is a new technique in earthquake engineering, its principle is quite simple, and it consists to create a discontinuity between the foundation and the superstructure, so that seismic energy cannot be completely transmitted into the structure.Therefore, this article includes a numerical application of the nonlinear static method, the capacity spectrum method (CSM), on two types of structures, fixed base structure and isolated base structure. The CSM is one of the methods used for the evaluation of seismic performance. Its principle consists in superimposing a curve which represents the capacity of the structure originated from a non-linear static analysis (Pushover), with a curve representing the solicitation brought by the earthquake. The intersection of these two curves represents the point performance, which evaluates the maximum displacement of the structure in the plastic domain.
隔震与固定基钢筋混凝土结构性能比较
地震将大量的能量传递给结构,造成结构的破坏。隔震技术可以吸收大量的地震能量。隔震概念是地震工程中的一项新技术,其原理相当简单,即在基础与上部结构之间制造一个不连续结构,使地震能量不能完全传递到结构中。因此,本文将非线性静力学方法——容量谱法(CSM)应用于两类结构,即固定基础结构和隔震基础结构。CSM是评价结构抗震性能的方法之一。它的原理是将一条表示由非线性静力分析(Pushover)产生的结构能力的曲线与一条表示地震带来的恳求的曲线叠加在一起。这两条曲线的交点表示点性能,用于评估结构在塑性域中的最大位移。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
7
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信