Evaluation of Five Automated Urine Analyzers as Screening Instruments for Enhancing Diagnostic Efficiency in Urinary Tract Infection

Jooyoung Cho, Jung-Hyun Byun, Sang-Guk Lee, Kyeongjin Oh, Beomchan Jeon, D. Yong, Jeong-Ho Kim
{"title":"Evaluation of Five Automated Urine Analyzers as Screening Instruments for Enhancing Diagnostic Efficiency in Urinary Tract Infection","authors":"Jooyoung Cho, Jung-Hyun Byun, Sang-Guk Lee, Kyeongjin Oh, Beomchan Jeon, D. Yong, Jeong-Ho Kim","doi":"10.5145/acm.2021.24.3.3","DOIUrl":null,"url":null,"abstract":"진단적 효율을 장비로서의 자동화 ABSTRACT Background: Although urine culture is considered a reference standard for the diagnosis of urinary tract infection (UTI), it is time-consuming, labor-intensive, and expensive. Here, we evaluated the performance of five recent automated urine analyzers for UTI diagnosis. Methods: For the 510 specimens analyzed, the criterion for ‘ significant bacteriuria’ was defined as ≥ 10 4 CFU/mL in the inoculated plate for all specimens or ≥ 10 3 CFU/mL for specimens from patients using a Foley catheter or with urinary symptoms. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of UTI were analyzed using indicators individually, in different combinations, or with various cut-off values. Results: Seventy-one specimens (13.9%) exhibited ‘ significant bacteriuria’. In the receiver operating characteristics curve analysis, UF-5000 (Sysmex Corp., Japan) showed the highest area under the curve values for both males and females (0.876 and 0.846, respectively). The PPVs for specimens from males with all indicators positive increased up to 100% after adjusting the cut-off values. NPVs for specimens with all indicators negative were 94.3%– in males and 78.1%–93.8% in females after adjusting the cut-off values. Conclusion: As a rapid and accurate diagnostic tool, urine sediment analyzers can be valuable for UTI diagnosis by reducing unnecessary culture and can help clinicians determine a treatment plan. The Cobas ® u701 and URiSCAN® PlusScope did not display the quantitative bacterial counts when our experiment was conducted. The iQ ® 200SPRINT provided ASP values instead of bacterial counts.","PeriodicalId":34065,"journal":{"name":"Annals of Clinical Microbiology","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Clinical Microbiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5145/acm.2021.24.3.3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

진단적 효율을 장비로서의 자동화 ABSTRACT Background: Although urine culture is considered a reference standard for the diagnosis of urinary tract infection (UTI), it is time-consuming, labor-intensive, and expensive. Here, we evaluated the performance of five recent automated urine analyzers for UTI diagnosis. Methods: For the 510 specimens analyzed, the criterion for ‘ significant bacteriuria’ was defined as ≥ 10 4 CFU/mL in the inoculated plate for all specimens or ≥ 10 3 CFU/mL for specimens from patients using a Foley catheter or with urinary symptoms. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of UTI were analyzed using indicators individually, in different combinations, or with various cut-off values. Results: Seventy-one specimens (13.9%) exhibited ‘ significant bacteriuria’. In the receiver operating characteristics curve analysis, UF-5000 (Sysmex Corp., Japan) showed the highest area under the curve values for both males and females (0.876 and 0.846, respectively). The PPVs for specimens from males with all indicators positive increased up to 100% after adjusting the cut-off values. NPVs for specimens with all indicators negative were 94.3%– in males and 78.1%–93.8% in females after adjusting the cut-off values. Conclusion: As a rapid and accurate diagnostic tool, urine sediment analyzers can be valuable for UTI diagnosis by reducing unnecessary culture and can help clinicians determine a treatment plan. The Cobas ® u701 and URiSCAN® PlusScope did not display the quantitative bacterial counts when our experiment was conducted. The iQ ® 200SPRINT provided ASP values instead of bacterial counts.
5种自动尿液分析仪对提高尿路感染诊断效率的评价
摘要背景:虽然尿液培养被认为是诊断尿路感染(UTI)的参考标准,但它耗时、费力且昂贵。在这里,我们评估了五种最新的自动尿液分析仪用于UTI诊断的性能。方法:在所分析的510份标本中,“显著菌尿”的标准定义为接种板中所有标本≥104 CFU/mL,或使用Foley导尿管或有泌尿系统症状的患者标本≥103 CFU/mL。采用单项指标、不同组合指标或不同截止值对UTI的敏感性、特异性、阳性预测值(PPV)、阴性预测值(NPV)进行分析。结果:71例(13.9%)出现“显著菌尿”。在受试者工作特征曲线分析中,男性和女性的曲线下面积最大的是f -5000 (Sysmex Corp., Japan),分别为0.876和0.846。调整临界值后,所有指标均为阳性的雄性标本的ppv增加到100%。调整临界值后,所有指标均为阴性的标本,雄性标本npv为94.3%,雌性标本npv为78.1% ~ 93.8%。结论:尿沉渣分析仪作为一种快速、准确的诊断工具,可以减少不必要的培养,对尿路感染的诊断有价值,可以帮助临床医生确定治疗方案。Cobas®u701和URiSCAN®PlusScope在我们进行实验时没有显示定量细菌计数。iQ®200SPRINT提供ASP值而不是细菌计数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
10
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书