Instantaneous Gain in Video Head Impulse Test: A Reliability Study

IF 0.7 Q4 OTORHINOLARYNGOLOGY
Burak Kabiş, H. Tutar, B. Gündüz, S. Aksoy
{"title":"Instantaneous Gain in Video Head Impulse Test: A Reliability Study","authors":"Burak Kabiş, H. Tutar, B. Gündüz, S. Aksoy","doi":"10.4274/tao.2022.2022-1-4","DOIUrl":null,"url":null,"abstract":"Objective: Vestibulo-ocular reflex gain at 40, 60, and 80 ms following the head movement start is calculated as the instantaneous gain. The purpose of this study was to investigate the reliability of instantaneous gain values at 40, 60, and 80 ms with testing and retesting in healthy adults. Methods: The study was conducted with Interacoustics EyeSeeCam vHIT (Interacoustics, Denmark), and 42 healthy adults were evaluated twice at half-hour intervals (test and retest) by the same practitioner. Agreement of mean gain, gain asymmetry, and instantaneous gain was evaluated using a paired samples t-test. Results: Mean age of the participants was 33.62±11.17; 38.1% were male and 61.9% were female. In the degree of the agreement, paired sample correlation (r) between test and retest results of the horizontal semicircular canals was found to be higher than those of the vertical semicircular canals. Moreover, the highest correlation between test and retest for instantaneous gain, calculated for only horizontal semicircular canals, was found at 80 ms on each side (0.791; 0.838, right and left, respectively), while the lowest correlation between these parameters was found between the gain asymmetry values. Conclusion: The video head impulse test used in studies calculates the mean gain in approximately at 60 ms. However, the higher correlation between mean gain values at 80 ms in our findings indicates that gain calculation strategies and techniques for latencies should be discussed. Additionally, the low correlation of vertical semicircular canals for mean gain and gain asymmetry between semicircular canal pairs, which clearly shows that more standard and more reliable methods should be developed.","PeriodicalId":44240,"journal":{"name":"Turkish Archives of Otorhinolaryngology","volume":"3 1 1","pages":"16 - 22"},"PeriodicalIF":0.7000,"publicationDate":"2022-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turkish Archives of Otorhinolaryngology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4274/tao.2022.2022-1-4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Vestibulo-ocular reflex gain at 40, 60, and 80 ms following the head movement start is calculated as the instantaneous gain. The purpose of this study was to investigate the reliability of instantaneous gain values at 40, 60, and 80 ms with testing and retesting in healthy adults. Methods: The study was conducted with Interacoustics EyeSeeCam vHIT (Interacoustics, Denmark), and 42 healthy adults were evaluated twice at half-hour intervals (test and retest) by the same practitioner. Agreement of mean gain, gain asymmetry, and instantaneous gain was evaluated using a paired samples t-test. Results: Mean age of the participants was 33.62±11.17; 38.1% were male and 61.9% were female. In the degree of the agreement, paired sample correlation (r) between test and retest results of the horizontal semicircular canals was found to be higher than those of the vertical semicircular canals. Moreover, the highest correlation between test and retest for instantaneous gain, calculated for only horizontal semicircular canals, was found at 80 ms on each side (0.791; 0.838, right and left, respectively), while the lowest correlation between these parameters was found between the gain asymmetry values. Conclusion: The video head impulse test used in studies calculates the mean gain in approximately at 60 ms. However, the higher correlation between mean gain values at 80 ms in our findings indicates that gain calculation strategies and techniques for latencies should be discussed. Additionally, the low correlation of vertical semicircular canals for mean gain and gain asymmetry between semicircular canal pairs, which clearly shows that more standard and more reliable methods should be developed.
视频头脉冲测试中的瞬时增益:可靠性研究
目的:计算头部运动开始后40,60,80ms的前庭眼反射增益作为瞬时增益。本研究的目的是研究在健康成人中测试和重新测试40、60和80 ms瞬时增益值的可靠性。方法:采用Interacoustics eyeeseecam vHIT (Interacoustics,丹麦)软件,对42名健康成人进行每隔半小时两次(测试和再测试)的评估。使用配对样本t检验评估平均增益、增益不对称和瞬时增益的一致性。结果:参与者平均年龄为33.62±11.17岁;男性占38.1%,女性占61.9%。在一致性程度上,水平半规管测试与重测结果的配对样本相关性(r)高于垂直半规管。此外,仅对水平半规管计算的瞬时增益的测试和重新测试之间的相关性最高,在每侧80 ms时发现(0.791;0.838,分别为右、左),而增益不对称值之间的相关性最低。结论:研究中使用的视频头脉冲测试计算了大约在60ms的平均增益。然而,在我们的研究结果中,80毫秒时的平均增益值之间的较高相关性表明,应该讨论增益计算策略和延迟技术。此外,垂直半规管与平均增益的相关性较低,半规管对之间的增益不对称,这清楚地表明需要开发更标准和更可靠的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信