Response Corridors for Blunt Impacts to the Back

IF 0.7 Q4 TRANSPORTATION SCIENCE & TECHNOLOGY
C. Parenteau, D. Viano, W. Hardy
{"title":"Response Corridors for Blunt Impacts to the Back","authors":"C. Parenteau, D. Viano, W. Hardy","doi":"10.4271/09-09-01-0003","DOIUrl":null,"url":null,"abstract":"Corridors for the biofidelity of blunt impact to the back are important for sled and crash testing with Anthropomorphic Test Devices (ATDs). The Hybrid III is used in rear sled tests as part of Federal Motor Vehicle Safety Standards (FMVSS) 202a. The only corridor for biofidelity is the neck extension. Eight Post Mortem Human Subjects (PMHS) were subjected to 20 blunt impacts with a 15.2 cm (6 in.) diameter pendulum weighing 23.4 kg. The impact was below T1 at 4.5 m/s and 6.7 m/s and below T6 at 4.5 m/s centered on the back. Head, neck, and chest responses were reported in 2001 [8]. In this study, the responses were scaled to the 50th male Hybrid III, and corridors were determined defining biofidelity for blunt impacts to the back. The scaled data gives an average peak force of 3.44 kN ± 0.74 kN at T1 and 4.5 m/s, 5.08 kN ± 1.35 kN at T1 and 6.7 ms, and 3.4 kN ± 1.2 kN at T6 and 4.5 m/s. The corresponding scaled deflection was 44.0 ± 19.7 mm, 60.2 ± 21.2 mm, and 53.1 ± 16.5 mm. The average stiffness of the back was 1.21 kN/cm at T1 and 4.5 m/s, 1.17 kN/cm at T1 and 6.7 m/s, and 1.14 kN/cm at T6 and 4.5 m/s. The corridors help to define biofidelity and can be used to assess the performance of the Hybrid III, Biofidelic Rear Impact Dummy (BioRID) II, and other ATDs.","PeriodicalId":42847,"journal":{"name":"SAE International Journal of Transportation Safety","volume":"1 1","pages":""},"PeriodicalIF":0.7000,"publicationDate":"2021-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SAE International Journal of Transportation Safety","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4271/09-09-01-0003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"TRANSPORTATION SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 1

Abstract

Corridors for the biofidelity of blunt impact to the back are important for sled and crash testing with Anthropomorphic Test Devices (ATDs). The Hybrid III is used in rear sled tests as part of Federal Motor Vehicle Safety Standards (FMVSS) 202a. The only corridor for biofidelity is the neck extension. Eight Post Mortem Human Subjects (PMHS) were subjected to 20 blunt impacts with a 15.2 cm (6 in.) diameter pendulum weighing 23.4 kg. The impact was below T1 at 4.5 m/s and 6.7 m/s and below T6 at 4.5 m/s centered on the back. Head, neck, and chest responses were reported in 2001 [8]. In this study, the responses were scaled to the 50th male Hybrid III, and corridors were determined defining biofidelity for blunt impacts to the back. The scaled data gives an average peak force of 3.44 kN ± 0.74 kN at T1 and 4.5 m/s, 5.08 kN ± 1.35 kN at T1 and 6.7 ms, and 3.4 kN ± 1.2 kN at T6 and 4.5 m/s. The corresponding scaled deflection was 44.0 ± 19.7 mm, 60.2 ± 21.2 mm, and 53.1 ± 16.5 mm. The average stiffness of the back was 1.21 kN/cm at T1 and 4.5 m/s, 1.17 kN/cm at T1 and 6.7 m/s, and 1.14 kN/cm at T6 and 4.5 m/s. The corridors help to define biofidelity and can be used to assess the performance of the Hybrid III, Biofidelic Rear Impact Dummy (BioRID) II, and other ATDs.
背部钝性撞击的反应走廊
对于使用拟人化测试装置(ATDs)进行雪橇和碰撞测试来说,确保钝冲击对背部生物保真度的走廊非常重要。作为联邦机动车辆安全标准(FMVSS) 202a的一部分,混合动力III用于后方雪橇测试。保持生物保真度的唯一通道是颈部伸展。8名死后人类受试者(PMHS)受到了直径15.2厘米(6英寸)、重23.4千克的摆锤的20次钝性撞击。以4.5 m/s和6.7 m/s为中心的冲击低于T1,以4.5 m/s为中心的冲击低于T6。2001年报告了头部、颈部和胸部的反应。在这项研究中,响应被缩放到第50个雄性杂交III,并确定了走廊,以确定钝性撞击对背部的生物保真度。换算后的数据显示,在T1和4.5 m/s时,平均峰值力为3.44 kN±0.74 kN;在T1和6.7 ms时,平均峰值力为5.08 kN±1.35 kN;在T6和4.5 m/s时,平均峰值力为3.4 kN±1.2 kN。相应的尺度挠度分别为44.0±19.7 mm、60.2±21.2 mm和53.1±16.5 mm。在T1和4.5 m/s时,背部的平均刚度为1.21 kN/cm,在T1和6.7 m/s时为1.17 kN/cm,在T6和4.5 m/s时为1.14 kN/cm。廊道有助于定义生物保真度,并可用于评估Hybrid III、Biofidelic Rear Impact Dummy (BioRID) II和其他atd的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
SAE International Journal of Transportation Safety
SAE International Journal of Transportation Safety TRANSPORTATION SCIENCE & TECHNOLOGY-
CiteScore
1.10
自引率
0.00%
发文量
21
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信